Impact of New York Heart Association classification, advanced age and patient-prosthesis mismatch on outcomes in aortic valve replacement surgery.
نویسندگان
چکیده
OBJECTIVES More elderly patients (>80 years of age) are being referred for aortic valve replacement (AVR) with or without CABG. Current risk stratification models may not accurately predict the preoperative risk in these patients. We sought to determine which perioperative variables were relevant in determining short-term (30-day to in-hospital) outcomes in our intuition's series of consecutive AVR and AVR+CABG surgeries. We constructed a novel variable, patient-prosthesis mismatch (PPM) in the presence of diminished functional status (NYHA) classification, and studied its role as a predictor of mortality risk. METHODS From 2006 to 2010, 509 patients undergoing AVR or AVR+CABG were evaluated. We created four groups based on the age and procedure (AVR >80, AVR+CABG >80, AVR <80 and AVR+CABG <80). PPM was defined as a calculated effective orifice area index value of ≤ 0.85, and it was calculated from manufacturer-generated charts. In-hospital and 30-day outcomes were assessed using the Chi-square and logistic regression analyses. RESULTS Overall observed 30-day mortality for all groups was lower (n = 8, 1.6%) than the STS-predicted mortality. Reoperation and PPM+NYHA class III-IV were associated with short-term mortality, but age >80 years was not. Octogenarians referred for surgery often had advanced heart failure. CONCLUSIONS Overall, short-term outcomes after AVR with or without CABG were excellent and lower than predicted by the STS model. The low risk of AVR with CABG supports the consideration for earlier surgical referral and intervention for patients with a high likelihood of aortic stenosis progression before the onset of advanced heart failure ensues, regardless of the age. This should help further decrease the already very low mortality observed in these series. Efforts to avoid PPM in the setting of advanced heart failure may improve short-term results in this subset of patients.
منابع مشابه
Mid-term impact of patient-prosthesis mismatch on young and middle-aged patients undergoing surgery due to severe aortic stenosis
Methods All patients younger than 70 years of age undergoing isolated aortic valve replacement from October 2005 to October 2011 were analyzed. Patient-prosthesis mismatch was defined as the indexed effective orifice area ≤ 0,85cm2/m2. We studied the impact of patient-prosthesis mismatch on mid-term overall mortality, cardiac events and New York Heart Association functional class using an analy...
متن کامل[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].
INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...
متن کاملAortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملIndexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.
OBJECTIVE After aortic valve replacement, the effects of a small functional prosthesis on the extent and pattern of regression of left ventricular hypertrophy and on clinical outcomes may be less significant in older patients with low cardiac output requirements. The objective of this study was therefore to determine whether patient-prosthesis mismatch affects left ventricular mass regression i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2012