Evaluation of orthodontic mini-implant placement: a CBCT study

نویسندگان

  • Shilpa Kalra
  • Tulika Tripathi
  • Priyank Rai
  • Anup Kanase
چکیده

BACKGROUND Optimal positioning of orthodontic mini-implants is essential for a successful treatment with skeletal anchorage. This study aims to compare the accuracy of two-dimensional radiographs with a cone beam computed tomography (CBCT) for mini-implant placement. METHODS An ideal site for mini-implant placement at the buccal interradicular space between the second premolar and the first molar was determined for 40 sites (in 13 patients aged 14 to 28 years) by using CBCT data. The mini-implant placement procedure was then divided into two groups. In CBCT group, mini-implants were placed at the sites determined from CBCT data. In RVG group, mini-implants were placed with the help of two-dimensional digital radiographs and a custom made guide. Postplacement CBCT scans were obtained to determine the accuracy of the mini-implant placement. The results were statistically analyzed with a Mann-Whitney test. RESULTS A statistically significant difference (p value=0.02) was observed between the two groups for deviation from an ideal height of placement of the mini-implants. Deviations in mesiodistal positioning and angular deviation showed a statistically non-significant difference. Three out of twenty mini-implants in the RVG group showed root contact in the mandibular arch that may be attributed to the narrower interradicular space and reduced accessibility in the mandibular posterior region. CONCLUSIONS Although CBCT provides an accurate three-dimensional visualization of the interradicular space, the two-dimensional intraoral radiograph of the interradicular area provides sufficient information for mini-implant placement. Considering the amount of radiation exposure and cost with the two techniques, it is recommended to use two-dimensional radiographs with a surgical guide for a routine mini-implant placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography

OBJECTIVES To evaluate the accuracy of using routine 2-dimensional (2D) radiographs (panoramic and periapical) when evaluating the position of orthodontic temporary anchorage devices (mini-implants) in the maxilla, and to compare the results to 3-dimensional cone-beam computed tomography (CBCT). METHODS This cross-sectional study was conducted at King Abdulaziz University, Faculty of Dentistr...

متن کامل

Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

PURPOSE The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol. MATERIALS AND METHODS Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 grou...

متن کامل

Interradicular Space in the Anterior Mandible on CBCT Scans of an Iranian Population

Abstract Background and Aim: This study aimed to assess the bone thickness at the interradicular spaces in the anterior mandible on cone-beam computed tomography (CBCT) scans of patients to find appropriate sites for mini-implant and miniscrew placement. Materials and Methods: This analytical cross-sectional study was conducted on 161 CBCT scans of patients (98 females and 63 male...

متن کامل

Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tub...

متن کامل

Patient’s Perception of Pain in Treatment with Temporary Anchorage Devices (Micro-implant, Mini-implant and Mini-plate): Intragroup and Intergroup Analysis

Currently, temporary anchorage devices (TADs) are being used in orthodontic treatments for skeletal anchorages. However, patients remain apprehensive regarding the use of this novel concept in orthodontic procedures. The purpose of this study was to compare the differences and the change in pain perception after treatment using TADs (micro-implant, mini-implant and mini-plate). Fifty-seven TADs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014