Technical note: use of a double inversion recovery pulse sequence to image selectively grey or white brain matter.

نویسندگان

  • T W Redpath
  • F W Smith
چکیده

The design of a double inversion recovery (DIR) sequence, to image selectively grey or white brain matter, is described. Suitable choice of inversion times allows either cerebrospinal fluid (CSF) and white matter to be suppressed, to image the cortex alone, or CSF and grey matter to be suppressed, to image the white matter. The DIR sequence was found to give clear delineation of the cerebral cortex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase Sensitive Inversion Recovery Magnetic Resonance Imaging of the Pediatric Brain

Introduction: Images with good grey/white matter contrast are important for determining normal developmental changes in the pediatric brain, primarily myelination but also cortical maturation. Conventional Tland TZweighted images offer some degree of grey/white matter contrast but any pulse sequence improvements would be beneficial, particularly for subtle changes occurring early in life. In th...

متن کامل

3D Double Inversion Recovery for High Resolution Gray Matter Brain Imaging

Gray matter (GM) images with high spatial resolution are obtained at 1.5T with a new multislab 3D double inversion recovery sequence that selectively suppresses cerebrospinal fluid (CSF) and white matter (WM). Images show a clear delineation of GM from WM and CSF, also for small GM structures such as the entorhinal cortex, of importance in Alzheimer's disease. Feasibility is demonstrated for th...

متن کامل

Improved Dual White Matter and CSF Suppression using MP-nRAGE

TARGET AUDIENCE: Researchers and clinicians that study gray matter or use double inversion recovery sequences. PURPOSE: Double inversion recovery (DIR) pulse sequences are commonly used to obtain images of gray matter (GM) by simultaneously suppressing the signal from white matter (WM) and CSF. Unfortunately, these DIR methods are typically slow with low SNR in the GM regions of interest. Recen...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

T1-weighted fluid-attenuated inversion recovery at low field strength: a viable alternative for T1-weighted intracranial imaging.

BACKGROUND AND PURPOSE T1-weighted spin-echo imaging has been widely used to study anatomic detail and abnormalities of the brain; however, the image contrast of this technique is often poor, especially at low field strengths. We tested a new pulse sequence, T1-weighted fluid-attenuated inversion recovery (FLAIR), which provides good contrast between lesions, surrounding edematous tissue, and n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 67 804  شماره 

صفحات  -

تاریخ انتشار 1994