Evaluation of Performance Requirements for Seismic Design of Piping System

ثبت نشده
چکیده

The cost of damage to the non-structural systems in critical facilities like nuclear power plants and hospitals can exceed 80% of the total cost of damage during an earthquake. The failure of nonstructural components, especially, piping systems led to leakage of water and subsequent shut-down of hospitals immediately after the event. Consequently, the evaluation of performance of these types of structural configurations has become necessary to mitigate the risk and to achieve reliable designs. This paper focuses on a methodology to evaluate the static and dynamic characteristics of complex actual piping system based on NFPA-13 and SMACNA guidelines. The result of this study revealed that current piping system subjected to design lateral force and design spectrum based on UBC-97 was failed in both cases and mode shapes between piping system and building structure were very different. Keywords—Nonstructural component, piping, hospital, seismic, bracing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Seismic Performance of Combined Horizontal and Vertical Hexagrid Structural System for High-rise Buildings

Summary In this study, the seismic performance of hexagrid structures which are composed of horizontal and vertical hexagrid by using a transitional story, has been investigated. To this end, 10 models of 50-story hexagrid structures were designed. 9 models with horizontal hexagrid cells which transited to vertical cells using a transitional story, and a model of completely horizontal hexagrid ...

متن کامل

Performance-Based Plastic Design of Moment Frame-Steel Plate Shear Wall as a Dual System

Steel Plate Shear Wall (SPSW) is an emerging seismic load-resistant system that, compared to other systems, enjoys the advantages of stable ductile behavior, fewer detailing requirements, rapid constructability, and economy. American seismic provisions decree that a SPSW should be designed as a moment frame with a web infill plate. Specifically, in case of buildings taller than 160 ft, it decre...

متن کامل

Experimental Evaluation of the Seismic Performance of Hospital Sprinkler Systems

This paper discusses the experimental set-up and procedures for the seismic testing and evaluation of a sprinkler system in hospital model. Concrete compression tests are ran to ensure compliance with ACI 355.2 anchor testing qualifications. Maximum shear strength of the anchor is found to include within the piping system model. Frame and piping system within the model is tested under input mot...

متن کامل

PERFORMANCE-BASED SEISMIC DESIGN OPTIMIZATION FOR MULI-COLUMN RC BRIDGE PIERS, CONSIDERING QUASI-ISOLATION

In this paper an optimization framework is presented for automated performance-based seismic design of bridges consisting of multi-column RC pier substructures. The beneficial effects of fusing components on seismic performance of the quasi-isolated system is duly addressed in analysis and design. The proposed method is based on a two-step structural analysis consisting of a linear modal dynami...

متن کامل

AN EFFICIENT METHOD FOR OPTIMUM PERFORMANCE-BASED SEISMIC DESIGN OF FUSED BUILDING STRUCTURES

A dual structural fused system consists of replaceable ductile elements (fuses) that sustain major seismic damage and leave the primary structure (PS) virtually undamaged. The seismic performance of a fused structural system is determined by the combined behavior of the individual PS and fuse components. In order to design a feasible and economic structural fuse concept, we need a procedure to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013