A randomised trial of supine versus prone breast radiotherapy (SuPr study): comparing set-up errors and respiratory motion.
نویسندگان
چکیده
PURPOSE To test a prone position against the international-standard supine position in women undergoing whole-breast-radiotherapy (WBRT) after wide-local-excision (WLE) of early breast cancer (BC) in terms of feasibility, set-up errors, and respiratory motion. METHODS Following WLE of BC with insertion of tumour-bed clips, patients underwent 4D-CT for WBRT-planning in supine and prone positions (the latter using an in-house-designed platform). Patients were randomised to undergo WBRT fractions 1-7 in one position, switching to the alternate position for fractions 8-15 (40Gy/15-fractions total). Cone-beam CT-images (CBCT) were acquired prior to fractions 1, 4, 7, 8, 11 and 14. CBCT data were matched to planning-CT data using (i) chest-wall and (ii) clips. Systematic and random errors were calculated. Maximal displacement of chest-wall and clips with respiration was measured on 4D-CT. Clinical- to planning-target-volume (CTV-PTV) margins were calculated. Patient-comfort-scores and treatment-times were evaluated. RESULTS Twenty-five patients were randomized. 192/192 (100%) planned supine fractions and 173/192 (90%) prone fractions were completed. 3D population systematic errors were 1.3-1.9mm (supine) and 3.1-4.3mm (prone) (p=0.02) and random errors 2.6-3.2mm (supine) and 3.8-5.4mm (prone) (p=0.02). Prone positioning reduced chest-wall and clip motion (0.5±0.2mm (prone) versus 2.7±0.5mm (supine) (p<0.001)) with respiration. Calculated CTV-PTV margins were greater for prone (12-16mm) than for supine treatment (10mm). Patient-comfort-scores and treatment times were comparable (p=0.06). CONCLUSIONS Set-up errors were greater using our prone technique than for our standard supine technique, resulting in the need for larger CTV-PTV margins in the prone position. Further work is required to optimize the prone treatment-platform and technique before it can become a standard treatment option at our institution.
منابع مشابه
Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملWhole breast and regional nodal irradiation in prone versus supine position in left sided breast cancer
BACKGROUND Prone whole breast irradiation (WBI) leads to reduced heart and lung doses in breast cancer patients receiving adjuvant radiotherapy. In this feasibility trial, we investigated the prone position for whole breast + lymph node irradiation (WB + LNI). METHODS A new support device was developed for optimal target coverage, on which patients are positioned in a position resembling a ph...
متن کاملبررسیمقایسهایمیزاناشباعاکسیژنخونشریانینوزاداننارسدچار سندرمدیسترستنفسیدر دو وضعیتدمر و طاقباز
Background : Neonatal period is one of the most important periods in human's life. Low birth weight and immaturity is often the cause of death. (weight less them 1000grm and pregnancy less than 30 weeks). One of the main cause of death in this period is respiratory distress syndrome. Objective : To determine the effect of prone and supine positioning oxygenation in preterm infants with resp...
متن کاملThe UK HeartSpare Study (Stage IB): Randomised comparison of the voluntary breath-hold technique and prone treatment in larger-breasted women
Purpose: To compare mean heart and left anterior descending coronary artery (LAD) doses (NTDmean) (Gy) and positional reproducibility in larger-breasted women receiving left breast radiotherapy using supine voluntary deep-inspiratory breath-hold (VBH) and free-breathing prone techniques in a nonblinded randomised-controlled crossover trial. Methods and materials: Following surgery for early bre...
متن کاملComparison of Extubation of Patients in Prone versus Supine Position in workers Undergoing Lumbar Disc Surgery
Introduction: This study compared the extubation of patients in prone versus supine positions in patients undergoing lumbar disc surgery. Methods: In this single-blind clinical trial, 60 patients who were candidates for elective lumbar disc surgery were selected and randomly assigned into two groups of 30 patients. All patients primarily underwent surgery in the prone position. After surgery a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
دوره 100 2 شماره
صفحات -
تاریخ انتشار 2011