TU-E-BRA-02: A Method to Remove Support Arm Backscatter from EPID Images.

نویسندگان

  • B King
  • P Greer
چکیده

PURPOSE To develop a method for removing the effect of support arm backscatter from Varian electronic portal imaging devices (EPIDs), improving the dosimetric abilities of the imager. METHODS A physical, kernel based model of the backscatter signal produced during an exposure was developed. The model parameters were determined through an optimization process, comparing measured images without arm backscatter (EPID removed from arm) to measured images that include arm backscatter. The backscatter model was used to develop a backscatter correction process that removes the support arm backscatter from measured EPID images. The correction process was tested by applying the method to measured images of 17 rectangular asymmetric fields and comparing the Result to off-arm images. The same process was repeated with 42 IMRT fields. RESULTS The backscatter removal process was able to effectively remove the arm backscatter from all of the measured images and accurately predict the measured off-arm images. Comparing the corrected images to the measured off-arm images, the mean absolute difference at the centre of each rectangular field was 0.29% (standard deviation 0.18%). This is an improvement over the uncorrected images which gave a mean difference of 1.01% (standard deviation 0.73%). The largest discrepancy observed with the corrected images was 0.6%, compared to 2.8% for the uncorrected images. Comparing the corrected IMRT images to the measured off-arm images, an overall mean gamma value of 0.28 (standard deviation 0.04) was found using 2%, 2mm criteria. Comparison of the uncorrected images to the measured off-arm images resulted in an overall mean gamma of 0.40 (standard deviation 0.10). CONCLUSIONS A method for accurately and reliably removing the effect of support arm backscatter from EPID images has been developed and extensively tested. The method can be applied to any measured EPID image and does not require any additional information about the exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved Monte-Carlo model of the Varian EPID separating support arm and rear-housing backscatter

Previous investigators of EPID dosimetric properties have ascribed the backscatter, that contaminates dosimetric EPID images, to its supporting arm. Accordingly, Monte-Carlo (MC) EPID models have approximated the backscatter signal from the layers under the detector and the robotic support arm using either uniform or non-uniform solid water slabs, or through convolutions with back-scatter kerne...

متن کامل

Evaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy

Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...

متن کامل

A field size specific backscatter correction algorithm for accurate EPID dosimetry.

PURPOSE Portal dose images acquired with an amorphous silicon electronic portal imaging device (EPID) suffer from artifacts related to backscattered radiation. The backscatter signal varies as a function of field size (FS) and location on the EPID. Most current portal dosimetry algorithms fail to account for the FS dependence. The ramifications of this omission are investigated and solutions fo...

متن کامل

SU-E-T-164: Clinical Implementation of ASi EPID Panels for QA of IMRT/VMAT Plans.

PURPOSE To investigate various issues for clinical implementation of aSi EPID panels for IMRT/VMAT QA. METHODS Six linacs are used in our clinic for EPID-based plan QA; two Varian Truebeams, two Varian 2100 series, two Elekta Infiniti series. Multiple corrections must be accounted for in the calibration of each panel for dosimetric use. Varian aSi panels are calibrated with standard dark fiel...

متن کامل

The physical characteristics of a SLIC-EPID for transmitted dosimetry

ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part24  شماره 

صفحات  -

تاریخ انتشار 2012