A precise DA converter realised with imprecise resistors
نویسندگان
چکیده
In the 2R/R converters imprecision of resistors introduces two types of error. Positive errors introduce a gap in the analog domain, while negative errors cause non-monotonicity in the input/output characteristics. Changing the resistor ratio from 2R/R to 2R/R, with R>R, we intentionally introduce an additional negative error in order to avoid resulting positive error gap. In this paper we propose a simple calibration of such 2R/R converter. Simulation results confirm that even with resistors tolerance of few percents we can achieve a converter with error as low as one hundredth of a percent of full scale. Key-Words: 2R/R converter, input/output characteristics, gap, calibration, max INL.
منابع مشابه
APPLICATION OF DEA FOR SELECTING MOST EFFICIENT INFORMATION SYSTEM PROJECT WITH IMPRECISE DATA
The selection of best Information System (IS) project from many competing proposals is a critical business activity which is very helpful to all organizations. While previous IS project selection methods are useful but have restricted application because they handle only cases with precise data. Indeed, these methods are based on precise data with less emphasis on imprecise data. This paper pro...
متن کاملDac for High Speed and Low Power Applications Using Abacus
This paper proposes a Chinese Abacus Digital-to-Analog Converter (DAC) for high speed and low power applications like audio and video applications. This circuit of DAC uses resister strings to get a good analog output. The designed DAC uses the algorithm of abacus. Instead of using binary code, here we use abacus code to control the switches. So the complexity and the area will be reduced autom...
متن کاملThe Efficiency of MSBM Model with Imprecise Data (Interval)
Data Envelopment Analysis (DEA) is a mathematical programming-based approach for evaluates the relative efficiency of a set of DMUs (Decision Making Units). The relative efficiency of a DMU is the result of comparing the inputs and outputs of the DMU and those of other DMUs in the PPS (Production Possibility Set). Also, in Data Envelopment Analysis various models have been developed in order to...
متن کاملInvestigation of Station Service Transformer Ferroresonance in Manitoba Hydro’s 230-kV Dorsey Converter Station
An investigation of ferroresonance in a 230-kV transformer is undertaken. Correct modelling of the iron-core losses and the direct magnetic coupling between phases are shown to be important in duplicating field observations. A brute-force time-domain method and an analytical method for displaying margins to ferroresonance on a parameter plane are compared. Following proposed bus modifications, ...
متن کاملBurst Mode Switched Capacitor Voltage Converter Modeling and Design
An inductorless switched capacitor (SC) DC-DC voltage converter and a model based on the averaging technique are presented. The model was validated through circuit level simulations for a SC converter designed using CMOS 0.18 um technology, capable to deliver output currents up to 100 mA at a regulated low ripple 3.3 V output voltage, for input voltages between 1.8 V and 3.2 V and can be used f...