Intraoperative spinal sonography in thoracic and lumbar fractures: evaluation of Harrington rod instrumentation.
نویسندگان
چکیده
Thirty-seven patients with thoracic and lumbar spine fractures were treated with Harrington rod instrumentation (HRI), and the progress and results of that surgery were monitored with intraoperative spinal sonography (IOSS). Adequate neural tissue decompression and spinal column alignment was achieved in less than one-half (14/31, 45%) of the patients in whom HRI was performed as the first step of the surgical procedure. As a result of these findings, further surgical maneuvers were performed which, in most cases, resulted in adequate spinal realignment and neural tissue decompression. In six patients, direct surgical reduction of displaced bone fragments was performed before HRI. Since total decompression of neural tissue may be important in patients with spinal cord or cauda equina injuries, it is recommended that IOSS be used in all cases of HRI for thoracic and lumbar spine fractures. The need to perform additional surgical maneuvers to accomplish neural tissue decompression may be obviated if intraoperative sonography shows adequate decompression with HRI alone.
منابع مشابه
Comparison between the effects of Harrington Rod and multisegmented instrumentations in sagittal plane correction of idiopathic scoliosis
Abstract Objective: To present the changes in projected thoracic hypokyphosis and the behavior of lumbar lordosis within and below the fusion and to compare these changes between the Harrington rod (HR) and posterior multisegmented hook instrumentation. Methods: 178 patients with idiopathic scoliosis, who had undergone posterior spinal fusion with Harrington technique (106 patients) or multise...
متن کاملIntraoperative sonographic monitoring of reduction of thoracolumbar burst fractures.
Intraoperative real-time sonography was used to monitor surgical reduction of acute thoracolumbar burst fractures in eight patients. Real-time sonography was performed after laminectomy through a saline-filled operative field using either a 5.0 or a 7.5 MHz transducer. Sonography was performed during Harrington rod distraction and during fracture reduction to confirm adequacy of decompression o...
متن کاملTadpole system as new lumbar spinal instrumentation
BACKGROUND There have been reports of serious complications associated with pedicle screw fixation, including nerve root injuries caused by accidental screw insertion. We have developed a new system of lumbar spinal instrumentation that we call Tadpole system. The purposes of this report were to show the results of a biomechanical study and the short-term outcome of a clinical study, as well as...
متن کاملشکست وسایل تثبیت ستون فقرات
This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...
متن کاملVertebral Compression Fractures after Lumbar Instrumentation
Lumbar spinal stenosis (LSS) is primarily found in an older population. This is a similar demographic group that develops both osteoporosis and vertebral compression fractures (VCF). This report reviewed a series of patients treated for VCF that had previous lumbar surgery for symptomatic spinal stenosis. Patients that only underwent laminectomy or fusion without instrumentation had a similar d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 145 2 شماره
صفحات -
تاریخ انتشار 1985