Discarding the initial aliquot of blood does not reduce contamination rates in intravenous-catheter-drawn blood cultures.
نویسندگان
چکیده
Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial 5 to 10 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures for adults. Thirty milliliters of blood was obtained aseptically. The first 10 ml, rather than being discarded, was inoculated into an aerobic culture vial. Using a second sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance (true versus contaminant). Out of 653 IVC-drawn blood culture pairs, both vials were contaminated in 38 pairs (5.8%); only the "discard" vial was contaminated in 33 (5.1%); and only the "standard" vial was contaminated in 31 (4.7%). Overall CR were 10.9% for the discard vial versus 10.5% for the standard vial (P = 0.90). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR.
منابع مشابه
Intravenous catheter blood cultures: utility and contamination.
OBJECTIVE In pediatrics, blood cultures (BCs) are often drawn as intravenous (IV) catheters are placed. This routine minimizes the number of painful and often difficult punctures a child must undergo but results in the discarding of multiple BC bottles when these cultures are later determined to be unnecessary. If the contamination rate of BCs drawn through an indwelling IV did not exceed the c...
متن کاملContamination rates of blood cultures obtained by dedicated phlebotomy vs intravenous catheter.
CONTEXT Blood culture is the criterion standard for identifying children with bacteremia. However, elevated false-positive rates are common and are associated with substantial health care costs. OBJECTIVE To compare contamination rates in blood culture specimens obtained from separate sites vs through newly inserted intravenous catheters. DESIGN, SETTING, AND PARTICIPANTS Observational stud...
متن کاملآلودگی باکتریال کشتهای خون مرکز طبی کودکان تهران - فروردین تا خرداد 1383
Background: Blood culture is the criterion standard for identifying children with bacteremia. However, elevated false-positive rates are common and are associated with substantial health care costs. The aims of this prospective study were to: 1) determine the rate of blood culture contamination 2) determine variety and frequency of contaminant bacteria 3) compare the duration of hospital stay a...
متن کاملContamination of catheter-drawn blood cultures.
To assess the risk of contamination, we reviewed retrospectively 1,408 matched pairs of simultaneous catheter-drawn and venipuncture blood cultures. Catheter-drawn cultures were equally likely to be truly positive (14.4 versus 13.7%) but more likely to be contaminated (3.8 versus 1.8% [P = 0.001]). Direct venipuncture cultures are preferred.
متن کاملDoes Tranexamic Acid Reduce Bleeding during Femoral Fracture Operation?
Background:Proximal Femoral shaft fractures are commonly associated with marked blood loss which can lead topostoperative acute anemia and some other complications.Tranexamic acid (TA) is an antifibrinolytic medication that reduces intra-and postoperative blood loss and transfusionrequirements during some elective surgeries (1-3).The aim of this study is to evaluate the effect of intravenous Tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 47 9 شماره
صفحات -
تاریخ انتشار 2009