Microchip electrophoresis with amperometric detection method for profiling cellular nitrosative stress markers.

نویسندگان

  • Dulan B Gunasekara
  • Joseph M Siegel
  • Giuseppe Caruso
  • Matthew K Hulvey
  • Susan M Lunte
چکیده

The overproduction of nitric oxide (NO) in cells results in nitrosative stress due to the generation of highly reactive species such as peroxynitrite and N2O3. These species disrupt the cellular redox processes through the oxidation, nitration, and nitrosylation of important biomolecules. Microchip electrophoresis (ME) is a fast separation method that can be used to profile cellular nitrosative stress through the separation of NO and nitrite from other redox-active intracellular components such as cellular antioxidants. This paper describes a ME method with electrochemical detection (ME-EC) for the separation of intracellular nitrosative stress markers in macrophage cells. The separation of nitrite, azide (interference), iodide (internal standard), tyrosine, glutathione, and hydrogen peroxide (neutral marker) was achieved in under 40 s using a run buffer consisting of 7.5 to 10 mM NaCl, 10 mM boric acid, and 2 mM TTAC at pH 10.3 to 10.7. Initially, NO production was monitored by the detection of nitrite (NO2(-)) in cell lysates. There was a 2.5- to 4-fold increase in NO2(-) production in lipopolysaccharide (LPS)-stimulated cells. The concentration of NO2(-) inside a single unstimulated macrophage cell was estimated to be 1.41 mM using the method of standard additions. ME-EC was then used for the direct detection of NO and glutathione in stimulated and native macrophage cell lysates. NO was identified in these studies based on its migration time and rapid degradation kinetics. The intracellular levels of glutathione in native and stimulated macrophages were also compared, and no significant difference was observed between the two conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual-channel Dual-electrode Microchip Electrophoresis with Electrochemical Detection for Voltammetric Identification of Cellular Nitrosative and Oxidative Stress Markers

This paper describes the development of a dual-channel microchip in a dual-parallel electrode configuration for voltammetric characterization of analytes in real time. The microchip system contains two distinct separation channels, each having a platinum working electrode set at a different potential. Two separate electropherograms were recorded and current ratios were generated based on the cu...

متن کامل

Separation and detection of peroxynitrite using microchip electrophoresis with amperometric detection.

Peroxynitrite (ONOO(-)) is a highly reactive species implicated in the pathology of several cardiovascular and neurodegenerative diseases. It is generated in vivo by the diffusion-limited reaction of nitric oxide (NO(*)) and superoxide anion ((*)O(2)(-)) and is known to be produced during periods of inflammation. Detection of ONOO(-) is made difficult by its short half-life under physiological ...

متن کامل

Indirect measurement of nitric oxide production by monitoring nitrate and nitrite using microchip electrophoresis with electrochemical detection.

An indirect method for monitoring nitric oxide (NO) by determining nitrate and nitrite using microchip capillary electrophoresis (CE) with electrochemical (EC) detection has been developed. This method combines determination of nitrite by direct amperometric detection following a microchip-based CE separation and conversion of nitrate to nitrite by chemical reduction using Cu-coated Cd granules...

متن کامل

Integration of amperometric sensors for microchip capillary electrophoresis application

Capillary electrophoresis is a technique for the separation and analysis of chemical compounds. Techniques adopted from the microchip technology knowledge have led to recent developments of electrophoresis system with integration on microchip. Microchip Capillary Electrophoresis (μCE) systems offer a series of advantages as easy integration for Lab-on-achip applications, high performance, porta...

متن کامل

Capillary electrophoresis microchip for direct amperometric detection of DNA fragments.

Detection and quantitation of nucleic acids have gained much importance in the last couple of decades, especially in the post-human genome project era. Such processes are tedious, time consuming and require expensive reagents and equipment. Therefore, in the present study, we demonstrated a simple process for the separation and analysis of small DNA fragments using capillary electrophoretic amp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 13  شماره 

صفحات  -

تاریخ انتشار 2014