Matrix-assisted ultraviolet laser-desorption ionization and electrospray-ionization time-of-flight mass spectrometry of sulfated neocarrabiose oligosaccharides.

نویسندگان

  • Yuko Fukuyama
  • Marina Ciancia
  • Hiroshi Nonami
  • Alberto S Cerezo
  • Rosa Erra-Balsells
  • María C Matulewicz
چکیده

Several commercial sulfated neocarrabiose oligosaccharides were analyzed by matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry (UV-MALDI-TOF-MS). UV-MALDI-TOF-MS was carried out in the linear and reflectron modes and, as routine, in both the positive- and negative-ion modes. 2,5-Dihydroxybenzoic acid and nor-harmane were used as matrices. In the positive- and negative-ion modes, with both matrices, peaks corresponding to (M+Na)(+) and (M-Na)(-) ions, respectively, were obtained, with only some signals due to glycosidic linkage cleavages (prompt fragmentation). With 2,5-dihydroxybenzoic acid abundant matrix signals were observed; nor-harmane afforded very few matrix signals in both ion modes, but more desulfation (prompt fragmentation) of the compounds occurred. When the desorption/ionization process was highly efficient, the post-source decay (PSD) fragmentation patterns were also investigated; most of the fragments detected derived from glycosidic linkage cleavages. Electrospray-ionization time-of-flight mass spectrometry (ESI-TOF-MS) in the negative-ion mode confirmed, with the observation of the (M-Na)(-) and the multiply charged anions, the identity and the purity of the samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of Mass Spectrometry to Structural Analysis of Marine Oligosaccharides

Marine oligosaccharides have attracted increasing attention recently in developing potential drugs and biomaterials for their particular physical and chemical properties. However, the composition and sequence analysis of marine oligosaccharides are very challenging for their structural complexity and heterogeneity. Mass spectrometry (MS) has become an important technique for carbohydrate analys...

متن کامل

Supporting Information Selenocysteine in Native Chemical Ligation and Expressed Protein Ligation

Instruments. NMR spectra were obtained with Bruker AC-300 and Varian UNITY-500 spectrometers. Mass spectra were obtained with Perkin Elmer Sciex API 365 electrospray ionization (ESI) and Bruker Biflex III matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) instruments at the University of Wisconsin Biotechnology Center. Ultraviolet and visible absorbance was recorded with a C...

متن کامل

Matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry of sulfated mannans from the red seaweed Nothogenia fastigiata.

Matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry (UV-MALDI-TOF-MS) was applied to sulfated xylo-mannan fractions from Nothogenia fastigiata in order to determine their molecular weights and distribution profiles. The number-average molecular weight calculated from the spectra was similar to that determined by chemical end-group analysis for the lower mole...

متن کامل

Matrix-assisted laser desorption/ionization mass spectrometric analysis of uncomplexed highly sulfated oligosaccharides using ionic liquid matrices.

Direct UV matrix-assisted laser desorption/ionization (MALDI) mass spectrometric analysis of uncomplexed, underivatized, highly sulfated oligosaccharides has been carried out using ionic liquids as matrices. Under conventionally used MALDI time-of-flight experimental conditions, uncomplexed polysulfated oligosaccharides do not produce any signal. We report that 1-methylimidazolium alpha-cyano-4...

متن کامل

Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification.

We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity ap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Carbohydrate research

دوره 337 17  شماره 

صفحات  -

تاریخ انتشار 2002