Some experimental errors in calculating regional cerebral blood flow from the intracarotid 133Xe clearance curve. A quantitative evaluation employing a digital model.
نویسندگان
چکیده
A digital model study has been developed for quantitative assessment of experimental errors in the analysis of 133Xe clearance curve from the brain. A small computer synthesized a model of the clearance curve, varying combinations of fast and slow components. The curves were convoluted with Poisson random digits to simulate statistical fluctuations. Identical curves were overlapped with varying intervals to study the influence of remaining activity. The height over area method to ten minutes was confirmed to overestimate CBF by 10% to 15% with a slow component of 20 ml/100 gm per minute, and the overstimation was increased with a lower slow flow component. The initial slope value was shown to have a close relationship with the fast flow component when the latter was less than 100 ml/100 gm per minute. Errors due to statistical fluctuations were determined only by the initial height (Ho cps), as the percent standard deviation was deltaHo/Ho in the height over area method and 2 deltaHo/HologHo in the initial slope method, where deltaHo equals square rootHo. Remaining activity caused errors of 1% to 3% in the initial slope method with an injection interval of 15 minutes. The influence of remaining activity can be eliminated with an injection interval of more than 25 to 30 minutes in the initial slope method and more than 40 minutes in the height over area method.
منابع مشابه
Some Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid Xe Clearance Curve A QUANTITATIVE EVALUATION EMPLOYING A DIGITAL MODEL
Some Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid Xe Clearance Curve • A digital model study has been developed for quantitative assessment of experimental errors in the analysis of Xe clearance curve from the brain. A small Computer synthesized a model of the clearance curve, varying combinations of fast and slow components. The curves were convoluted w...
متن کاملSome Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid
Some Experimental Errors in Calculating Regional Cerebral Blood Flow From the Intracarotid Xe Clearance Curve • A digital model study has been developed for quantitative assessment of experimental errors in the analysis of Xe clearance curve from the brain. A small Computer synthesized a model of the clearance curve, varying combinations of fast and slow components. The curves were convoluted w...
متن کاملRegional cerebral blood flow measured by the gamma camera after direct injection of 133Xe into the distal stump of the occluded middle cerebral artery.
Regional cerebral blood flow (rCBF) was measured after intracarotid injection of 133Xe concurrently with measurements of local cerebral blood flow (LCBF) after injection of 133Xe directly into the distal stump of the occluded middle cerebral artery (MCA) by the use of the gamma camera after producing experimental ischemia in baboons by occluding the MCA. Regional MCA stump pressure (rMCAP) was ...
متن کاملSpectrum subtraction technique for minimizing extracranial influence on cerebral blood flow measurements by 133xenon inhalation.
Estimates of regional cerebral blood flow (rCBF) by the 133Xe inhalation method are influenced by isotope contamination from slow clearing extracerebral tissues. Subtraction of x-ray (31 kev) from gamma-ray counts (81 kev) has been suggested as a means of yielding clearance curves that are relatively free of such contamination. In the present study, rCBF measurements based on the total 133Xe sp...
متن کاملStochastic analysis of 133xe clearance for determining regional cerebral blood flow in a primate model.
A technique for stochastic analysis of 133Xe washout using a computer-assisted Anger camera is described. The technique produces functional maps of both regional cerebral blood flow (rCBF) and error in rCBF. The calculational limitations of the technique are discussed and an experimental estimate made of the physical limitations associated with the low energy photon emitted by 133Xe. The method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 6 4 شماره
صفحات -
تاریخ انتشار 1975