Electrode-less measurement of cell layers impedance.
نویسندگان
چکیده
This paper is devoted to yet unpublished electrode-less methods (ELM) of cell layers impedance measurement based on transformer principle. The main advantage of ELM is elimination uncertainties caused by interface between electrodes and measured electrolyte. The method of avoiding distortion caused by non-ideal transformer transfer function ("deconvolution") and errors caused by residual voltage is described. The modification of original transformer based method allowing to measure an impedance of inserted object is proposed. Results of several calibration measurements confirming the proper function of ELM including example of transepithelial resistance of cells layer are presented. Crucial parts of measuring system and recommendation for their realization are included.
منابع مشابه
Basic study of a diagnostic modality employing a new electrical impedance tomography (EIT) method for noninvasive measurement in localized tissues.
The objective of this study is to develop a device for noninvasive local tissue electrical impedance tomography (EIT) using divided electrodes with guard electrodes and to validate its effectiveness using bioequivalent phantoms. For this purpose, we prepared a measurement device and bioequivalent phantoms, measured the electrical characteristics of the phantoms, and validated the method using t...
متن کاملTheorical Investigation of Linear Response for Passivated Metallic Electrode Under Potential Step (RESEARCH NOTE)
The transient response of passivated metallic electrode system under potential step was analyzed based on a linear model, and a technique for calculating the parameters characterizing the growth and dissolution of passive film was proposed. It is believed that the information which is expected to be gained from the impedance measurement can be obtained by this technique and that this technique ...
متن کاملReducing Impedance Fluctuation by Electrode Structure for Electrochemical Impedance Spectroscopy
In this paper, we investigated the electrode structure of the electrical bio-sensor to reduce impedance measurement fluctuation. Five pairs of the same electrodes were formed on the PCB substrate, and a fluidic channel was constructed with a double-sided tape and polycarbonate cover so that all the electrodes had the same reagent distribution. In order to find an electrode structure with little...
متن کاملSingle walled carbon nanotube in the reaction layer of gas diffusion electrode for oxygen reduction reaction
In this paper, the effect of surface area of reaction layers in gas diffusion electrodes on oxygen reduction reaction was investigated. For this purpose, various amounts (0.1, 0.2, 0.3, 0.4, 0.5, 1, 1.5 and zero %wt of total loading of reaction layer) of single walled carbon nanotube (SWCNT) were inserted in the reaction layer. The performance of gas diffusion electrodes for oxygen reduction re...
متن کاملDetermination of abdominal fat thickness using dual electrode separation in the focused impedance method (FIM).
Subcutaneous fat layer thickness in the abdomen is a risk indicator of several diseases and disorders like diabetes and heart problems and could be used as a measure of fitness. Skinfold measurement using mechanical calipers is simple but prone to error. Ultrasound scanning techniques are yet to be established as accurate methods for this purpose. magnetic resonance imaging (MRI) and computed t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological research
دوره 63 6 شماره
صفحات -
تاریخ انتشار 2014