Application of Capacitive Energy Storage Unit for Automatic Generation Control of Two Area Two Unit Power System
نویسنده
چکیده
This paper is about the application of Capacitive Energy Storage unit (CES) to two area two unit powersystem to improve dynamic performance of automatic generation control. Simulation is done without CES, with CES unit by taking frequency error as control input and with CES unit by taking Area Control Error (ACE) as Control input. Simulation studies show that CES units are capable of reducing the settling time of the responses. Simulation study also reveals that the dynamic responses with frequency deviations as feedback to CES are better than that obtained with ACE as feedback to CES unit and far superior than that without CES units.
منابع مشابه
Automatic Generation Control of an Interconnected Power System with Capacitive Energy Storage
This paper is concerned with the application of small rating Capacitive Energy Storage units for the improvement of Automatic Generation Control of a multiunit multiarea power system. Generation Rate Constraints are also considered in the investigations. Integral Squared Error technique is used to obtain the optimal integral gain settings by minimizing a quadratic performance index. Simulation ...
متن کاملSmart Grid Unit Commitment with Considerations for Pumped Storage Units Using Hybrid GA-Heuristic Optimization Algorithm
A host of technologies has been developed to achieve these aims of the smart grid. Some of these technologies include plug-in electric vehicle, demand response program, energy storage system and renewable distributed generation. However, the integration of the smart grid technologies in the power system operation studies such as economic emission unit commitment problem causes two major challen...
متن کاملUnit Commitment in Presence of Wind Power Plants and Energy Storage
As renewable energy increasingly penetrates into power grid systems, new challenges arise for system operators to keep the systems reliable under uncertain circumstances, while ensuring high utilization of renewable energy. This paper presents unit commitment (UC) which takes into account the volatility of wind power generation. The UC problem is solved with the forecasted intermittent wind pow...
متن کاملDesign of Fuzzy Logic Based PI Controller for DFIG-based Wind Farm Aimed at Automatic Generation Control in an Interconnected Two Area Power System
This paper addresses the design procedure of a fuzzy logic-based adaptive approach for DFIGs to enhance automatic generation control (AGC) capabilities and provide better dynamic responses in multi-area power systems. In doing so, a proportional-integral (PI) controller is employed in DFIG structure to control the governor speed of wind turbine. At the first stage, the adjustable parameters of ...
متن کاملPower Management in a Utility Connected Micro-Grid with Multiple Renewable Energy Sources
As an efficient alternative to fossil fuels, renewable energy sources have attained great attention due to their sustainable, cost-effective, and environmentally friendly characteristic. However, as a deficiency, renewable energy sources have low reliability because of their non-deterministic and stochastic generation pattern. The use of hybrid renewable generation systems along with the storag...
متن کامل