Simultaneous determination of vitamins D2 and D3 by LC-MS/MS in infant formula and adult nutritionals: First Action 2011.13.

نویسندگان

  • Donald L Gilliland
  • Charles K Black
  • James E Denison
  • Charles T Seipelt
چکیده

During the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" held on June 29, 2011, an Expert Review Panel (ERP) on behalf of AOAC INTERNATIONAL adopted the method "Simultaneous Determination of Vitamins D2 and D3 by LC-MS/MS in Infant Formula and Adult Nutritionals" as an AOAC Official First Action method. Vitamins D2 and D3 are extracted from the sample using pentane-ether; the extract is collected and dried under nitrogen. Vitamin D is separated from interfering compounds using UPLC, and quantitated using tandem mass spectrometry (MS/MS). Preliminary data showed the intermediate precision ranged from 3.34-8.05% and an accuracy range of 98.5-111% over the samples tested for vitamin D3. For vitamin D2, the intermediate precision ranged from 2.37-5.45% and accuracy ranged from 96.4-104% over the four matrixes evaluated. The analytical range for the method is bounded by the concentrations of the working standards, 21-270 ng/mL, and is equivalent to 0.168-2.16 mcg/100 g in ready-to-feed product. The practical method quantitation limit is 0.168 mcg/100 g product with method detection limit of 60 ng/100 g product. The ERP reviewed the data and determined that the performance characteristics of the method met the standard method performance requirements, and therefore the method was granted First Action status.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of vitamins D2 and D3 in infant formula and adult nutritionals by ultra-pressure liquid chromatography with tandem mass spectrometry detection (UPLC-MS/MS): First Action 2011.12.

The method for the "Determination of Vitamins D2 and D3 in Infant Formula and Adult Nutritionals by Ultra-Pressure Liquid Chromatography with Tandem Mass Spectrometry Detection (UPLC-MS/MS)" was adopted as AOAC Official First Action during the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" held June 29, 2011. During the meeting, an Expert Review Pan...

متن کامل

Application of ultra-high-performance liquid chromatography/tandem mass spectrometry for the measurement of vitamin D in infant formula and adult/pediatric nutritional formula: First Action 2011.11.

In an effort to measure vitamin D, ultra-high-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) was applied to samples. The use of UHPLC-MS/MS decreased the run time by 50%. The UHPLC-MS/MS achieved equal or better separation efficiency with complex food matrixes compared to HPLC-MS/MS. It was also observed that under the optimized conditions of UHPLC, all previtamin...

متن کامل

Determination of total folates in infant formula and adult nutritionals by trienzyme extraction and UPLC-MS/MS Quantitation: First Action 2011.06.

The method for "Determination of Total Folates in Infant Formula and Adult Nutritionals by Trienzyme Extraction and UPLC-MS/MS Quantitation" was submitted to the Folate Working Group for consideration for adoption as Official First Action by AOAC INTERNATIONAL. This method uses ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) to determine the total folates in infant...

متن کامل

Rapid and simultaneous determination of 25-OH-vitamin D2 and D3 in human serum by LC/MS/MS: Validation and uncertainty assessment

25-OH Vitamin D3 and 25-OH Vitamin D2 were determined by rapid, simple and validated LC/MS/MS method without using SPE and isotopic standard. The relative standard deviations (RSD) were found to be 3.1 and 2.8 % for 25-OH Vitamin D3 and 25-OH Vitamin D2, respectively. The correlation coefficient was grater than 0.99 for both analytes in the calibration range. The recoveries at 100 μg L concentr...

متن کامل

Analysis of Vitamin D2 and Vitamin D3 in Fortified Milk Powders and Infant and Nutritional Formulas by Liquid Chromatography-Tandem Mass Spectrometry: Single-Laboratory Validation, First Action 2016.05.

A method for the determination of vitamin D2 and vitamin D3 in fortified milk powders and infant and adult nutritional formulas is described. Samples are saponified at high temperature and lipid-soluble components are extracted into isooctane. A portion of the isooctane layer is transferred and washed, and an aliquot of 4-phenyl-1,2,4-triazoline-3,5-dione is added to derivatize the vitamin D to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 95 3  شماره 

صفحات  -

تاریخ انتشار 2012