The Clock Drawing Test for dementia of the Alzheimer's type: A comparison of three scoring methods in a memory disorders clinic.
نویسندگان
چکیده
OBJECTIVES To examine the reliability and validity of the Clock Drawing Test when used as a cognitive screening instrument for mild to moderate dementia, and to compare different scoring mechanisms. DESIGN Retrospective analysis of clock drawing performance using three published scoring methods (Shulman, Sunderland and Wolf-Klein). SETTING Hospital-based memory disorders clinic. PARTICIPANTS A sample of 28 consecutive patients attending the memory clinic for assessment who were given a diagnosis of Alzheimer's disease (mild or moderate) and 28 age- and sex-matched control subjects comprising 17 memory clinic attenders found to be normal and 11 community volunteers. MEASUREMENTS Sensitivity and specificity of the three clock rating scales against memory clinic diagnoses of dementia using DSM-III-R; their respective interrater reliabilities; and comparisons of each with measures of cognitive impairment (the Mini-Mental State Examination and the Blessed Orientation-Information-Memory-Concentration Test), daily performance of basic and instrumental activities (the Blessed Dementia Scale) and depression (the Hamilton Rating Scale for Depression). RESULTS All methods of scoring the Clock Drawing Test correlated well with measures of cognitive impairment (r = 0.57-0.73) and daily performance (r = 0.38-0.48), were independent of mild depression and demonstrated high sensitivity, specificity and interrater reliability. While all clock scales identified mild to moderate dementia reasonably well, the Shulman method performed best. In screening for dementia, clock drawing proved superior to the MMSE: 24/28 vs 20/28 cases identified. When compared with the MMSE, clock drawing provided additional diagnostic discrimination, identifying 7/8 AD patients with MMSE scores = 24. CONCLUSIONS In a clinic population, clock drawing, especially if scored according to the Shulman scale and combined with the MMSE, is an extremely efficient test screening measure for mild to moderate dementia of the Alzheimer's type with low false negative and false positive rates. This may have implications for screening elderly populations.
منابع مشابه
Clock drawing test ratings by dementia specialists: interrater reliability and diagnostic accuracy.
The authors conducted a study of clock drawing test scoring by dementia specialists to determine interrater reliability and diagnostic accuracy. The authors randomly assigned 25 clocks from each of six predetermined groups based on consensus diagnosis (cognitive comparison subjects, subjects with a memory complaint but with normal neuropsychological testing, subjects with probable and possible ...
متن کاملThe recent development in synthesis and pharmacological evaluation of small molecule to treat Alzheimer's diseases: A review
Alzheimer's disease is a neurological disorder in which the death of brain cells causes memory loss and cognitive decline. A neurodegenerative type of dementia, the disease starts mild and gets progressively worse. Like all types of dementia, Alzheimer's is caused by brain cell death. The most common presentation marking Alzheimer's dementia is where symptoms of memory loss are the most promine...
متن کاملThe recent development in synthesis and pharmacological evaluation of small molecule to treat Alzheimer's diseases: A review
Alzheimer's disease is a neurological disorder in which the death of brain cells causes memory loss and cognitive decline. A neurodegenerative type of dementia, the disease starts mild and gets progressively worse. Like all types of dementia, Alzheimer's is caused by brain cell death. The most common presentation marking Alzheimer's dementia is where symptoms of memory loss are the most promine...
متن کاملLongitudinal Changes in Clock Drawing Test (CDT) Performance before and after Cognitive Decline
BACKGROUND Many scoring systems exist for clock drawing task variants. However, none of them are reliable in evaluating longitudinal changes of cognitive function. The purpose of this study is to create a simple yet optimal scoring procedure to evaluate cognitive decline using a clinic-based sample. METHODS Clock-drawings from 121 participants (76 individuals with no dementia and later did no...
متن کاملThe use of the Clock Drawing Test in bipolar disorder with or without dementia of Alzheimer's type.
There is limited data regarding the cognitive profile from screening tests of older adults with bipolar disorder (BD) with dementia. Objective To investigate the Clock Drawing Test (CDT) among older adults with BD with and without Alzheimer's disease (AD). Method 209 older adults (79 with BD without dementia and 70 controls; 60 with AD, being 27 with BD) were included to evaluate the performanc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of geriatric psychiatry
دوره 12 6 شماره
صفحات -
تاریخ انتشار 1997