Consistency of pacing and metabolic responses during 2000-m rowing ergometry.

نویسندگان

  • Thomas I Gee
  • Duncan N French
  • Karl C Gibbon
  • Kevin G Thompson
چکیده

PURPOSE This study investigated the pacing strategy adopted and the consistency of performance and related physiological parameters across three 2000-m rowing-ergometer tests. METHODS Fourteen male well-trained rowers took part in the study. Each participant performed three 2000-m rowing-ergometer tests interspersed by 3-7 d. Throughout the trials, respiratory exchange and heart rate were recorded and power output and stroke rate were analyzed over each 500 m of the test. At the completion of the trial, assessments of blood lactate and rating of perceived exertion were measured. RESULTS Ergometer performance was unchanged across the 3 trials; however, pacing strategy changed from trial 1, which featured a higher starting power output and more progressive decrease in power, to trials 2 and 3, which were characterized by a more conservative start and an end spurt with increased power output during the final 500 m. Mean typical error (TE; %) across the three 2000-m trials was 2.4%, and variability was low to moderate for all assessed physiological variables (TE range = 1.4-5.1%) with the exception of peak lactate (TE = 11.5%). CONCLUSIONS Performance and physiological responses during 2000-m rowing ergometry were found to be consistent over 3 trials. The variations observed in pacing strategy between trial 1 and trials 2 and 3 suggest that a habituation trial is required before an intervention study and that participants move from a positive to a reverse-J-shaped strategy, which may partly explain conflicting reports in the pacing strategy exhibited during 2000-m rowing-ergometer trials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An analysis of the pacing strategy adopted by elite competitors in 2000 m rowing.

OBJECTIVES To determine the pacing strategies adopted by elite rowers in championship 2000 m races. METHODS Split times were obtained for each boat in every heavyweight race of the Olympic Games in 2000 and World Championships in 2001 and 2002, and the top 170 competitors in the British Indoor Rowing Championships in 2001 and 2002. Data were only included in subsequent analysis if there was g...

متن کامل

Comparison of rowing on a concept 2 stationary and dynamic ergometer.

Biomechanical and physiological responses to rowing 1000 m at a power output equivalent to a 2000 m race were compared in 34 collegiate rowers (17 women, 17 men) rowing on a stationary and dynamic Concept 2 ergometer. Stroke ratio, peak handle force, rate of force development, impulse, and respiratory exchange ratio decreased by 15.7, 14.8, 10.9, 10.2 and 1.9%, respectively, on the dynamic ergo...

متن کامل

Self-paced exercise is less physically challenging than enforced constant pace exercise of the same intensity: influence of complex central metabolic control.

OBJECTIVE To examine whether self-pacing reduces the physiological challenge of performing 5000 m rowing ergometry exercise in comparison with a matched-intensity exercise condition in which a constant effort pacing strategy is enforced. METHODS Nine healthy well-trained male participants volunteered to participate in three 5000 m rowing conditions (two submaximal and one maximal conditions) ...

متن کامل

Is three-dimensional anthropometric analysis as good as traditional anthropometric analysis in predicting junior rowing performance?

With the use of three-dimensional whole body scanning technology, this study compared the 'traditional' anthropometric model [one-dimensional (1D) measurements] to a 'new' model [1D, two-dimensional (2D), and three-dimensional (3D) measurements] to determine: (1) which model predicted more of the variance in self-reported best 2000-m ergometry rowing performance; and (2) what were the best anth...

متن کامل

Phase I and Phase II oxygen uptake kinetics during atrioventricular dyssynchrony in chronotropically competent pacemaker patients.

OBJECTIVE To elucidate the effects of atrioventricular (AV) dyssynchrony on phase I and phase II oxygen uptake (V(O2)) kinetics in chronotropically competent pacemaker patients during exercise of an intensity comparable to activities of daily living. DESIGN Blinded patients completed sub-ventilatory threshold (VT) work rate (WR) cycle ergometry exercise in random order during asynchronous AV ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of sports physiology and performance

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2013