A Risk Assessment of the Jaffe vs Enzymatic Method for Creatinine Measurement in an Outpatient Population
نویسندگان
چکیده
BACKGROUND The Jaffe and enzymatic methods are the two most common methods for measuring serum creatinine. The Jaffe method is less expensive than the enzymatic method but is also more susceptible to interferences. Interferences can lead to misdiagnosis but interferences may vary by patient population. The overall risk associated with the Jaffe method depends on the probability of misclassification and the consequences of misclassification. This study assessed the risk associated with the Jaffe method in an outpatient population. We analyzed the discordance rate in the estimated glomerular filtration rate based on serum creatinine measurements obtained by the Jaffe and enzymatic method. METHODS Method comparison and risk analysis. Five hundred twenty-nine eGFRs obtained by the Jaffe and enzymatic method were compared at four clinical decision limits. We determined the probability of discordance and the consequence of misclassification at each decision limit to evaluate the overall risk. RESULTS We obtained 529 paired observations. Of these, 29 (5.5%) were discordant with respect to one of the decision limits (i.e. 15, 30, 45 or 60 ml/min/1.73m2). The magnitude of the differences (Jaffe result minus enzymatic result) were significant relative to analytical variation in 21 of the 29 (72%) of the discordant results. The magnitude of the differences were not significant relative to biological variation. The risk associated with misclassification was greatest at the 60 ml/min/1.73m2 decision limit because the probability of misclassification and the potential for adverse outcomes were greatest at that decision limit. CONCLUSION The Jaffe method is subject to bias due to interfering substances (loss of analytical specificity). The risk of misclassification is greatest at the 60 ml/min/1.73m2 decision limit; however, the risk of misclassification due to bias is much less than the risk of misclassification due to biological variation. The Jaffe method may pose low risk in selected populations if eGFR results near the 60 ml/min/1.73m2 decision limit are interpreted with caution.
منابع مشابه
Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles.
BACKGROUND Standardized calibration does not change a creatinine measurement procedure's susceptibility to potentially interfering substances. METHODS We obtained individual residual serum or plasma samples (n = 365) from patients with 19 different disease categories associated with potentially interfering substances and from healthy controls. Additional sera at 0.9 mg/dL (80 μmol/L) and 3.8 ...
متن کاملApplicability of common reference intervals for serum creatinine concentrations to the Croatian population.
BACKGROUND In accordance with an ongoing activity for worldwide harmonization based on traceability in laboratory methods, the goal of this study was to validate the applicability of recommended "common" reference intervals for serum creatinine concentrations using a specific enzymatic method to the Croatian population. METHODS The reference group consisted of 240 healthy subjects (120 males ...
متن کاملPrime time for enzymatic creatinine methods in pediatrics.
BACKGROUND The literature regarding the nonspecificity of applications of the Jaffe (alkaline picrate) reaction for creatinine is generally outdated. We conducted a specificity study to update the nonspecificity information for current Jaffe and enzymatic creatinine assays. METHODS Two serum pools with creatinine concentrations within the pediatric reference interval were spiked with albumin,...
متن کاملEnzymatic creatinine assays allow estimation of glomerular filtration rate in stages 1 and 2 chronic kidney disease using CKD-EPI equation.
The National Kidney Disease Education Program group demonstrated that MDRD equation is sensitive to creatinine measurement error, particularly at higher glomerular filtration rates. Thus, MDRD-based eGFR above 60 mL/min/1.73 m² should not be reported numerically. However, little is known about the impact of analytical error on CKD-EPI-based estimates. This study aimed at assessing the impact of...
متن کاملPaired measurement of urinary creatinine in neonates based on a Jaffe and an enzymatic IDMS-traceable assay
BACKGROUND Urinary creatinine can be quantified by Jaffe or enzymatic assays and is commonly used as denominator of urinary excretion of electrolytes or protein. Paired analysis in pediatric and adult samples documented inter-assay differences (up to 80%). We verified the interchangeability of two IDMS-traceable assays (Jaffe and enzymatic) for neonatal urine and report on neonatal urinary crea...
متن کامل