Left Ventricular Function Assessment of Regional and Global Left Ventricular Function by Reinjection Tl-201 and Rest Tc-99m Sestamibi ECG-Gated SPECT Comparison With Three-Dimensional Magnetic Resonance Imaging
نویسندگان
چکیده
METHODS Reinjection-g-SPECT, MIBI-g-SPECT, and three-dimensional magnetic resonance imaging (3DMRI) were conducted in 20 patients with coronary artery disease. Regional wall motion (RWM) and wall thickening (RWT) were analyzed using semiquantitative visual scoring by each g-SPECT and 3DMRI. The left ventricular end-systolic and end-diastolic volumes (EDV, ESV) and LVEF estimated by reinjectionand MIBI-g-SPECT were compared with the results of 3DMRI.
منابع مشابه
The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملQuantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT.
UNLABELLED This study investigates the feasibility of routine clinical 201Tl gated perfusion SPECT (gated Tl), and compares quantitative left ventricular ejection fraction (LVEF) and visually-assessed regional wall motion and thickening to analogous values obtained from 99mTc-sestamibi gated perfusion SPECT (gated MIBI). METHODS We studied 121 patients with a rest gated Tl (3-3.5 mCi, 35 sec/...
متن کاملValue of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging.
OBJECTIVES The purpose of this study was to determine how frequently and for what reasons the addition of electrocardiographically gated technetium-99m (Tc-99m) sestamibi single-photon emission computed tomographic (SPECT) images add value to nongated SPECT perfusion images. BACKGROUND Electrocardiographic gating of Tc-99m sestamibi SPECT images permits assessment of regional and global left ...
متن کاملQuantitative rest technetium-99m tetrofosmin imaging in predicting functional recovery after revascularization: comparison with rest-redistribution thallium-201.
OBJECTIVES This study was undertaken to 1) compare the regional myocardial tracer distributions between rest technetium (Tc)-99m tetrofosmin and rest-redistribution thallium (Tl)-201 images in patients with coronary artery disease and left ventricular dysfunction; and 2) assess the comparative values of these agents for predicting functional recovery after revascularization. BACKGROUND Tc-99m...
متن کامل