Single-shot Resolution of X-ray Monitor Using Coded Aperture Imaging
نویسندگان
چکیده
We report on tests of an x-ray beam size monitor based on coded aperture imaging[1]. This technique uses a mask pattern to modulate incoming photons, with the resulting image being deconvolved through the mask and detector responses, including the effects of diffraction and attenuation materials in the path, over the spectral and angular distribution of the synchrotron radiation generated by the beam. We have tested mask patterns called URA masks[2], which have relatively flat spatial frequency response, and an open aperture of 50% for high-flux throughput, enabling single-shot (bunch-bybunch, turn-by-turn) measurements without the need for heat-sensitive mirrors. Bunch size measurements of ~10 micron bunches with single-shot (statistics-dominated) resolutions of ~2.5 microns have been demonstrated at CesrTA, and single-shot measurements with similar or better resolution of beams in the ~5 micron range are being aimed for at the ATF2. A beam-size monitor based on these principles is also being designed for the SuperKEKB low-emittance rings. We present estimated single-shot resolutions, along with a comparison to single-shot resolution measurements made at CesrTA.
منابع مشابه
Imaging Analysis of the Hard X-ray Telescope ProtoEXIST2 and New Techniques for High Resolution Coded Aperture Telescopes
Wide-field (& 100 deg) hard X-ray coded-aperture telescopes with high angular resolution (. 2′) will enable a wide range of time domain astrophysics. For instance, transient sources such as gammaray bursts can be precisely localized without assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging int...
متن کاملA Super-high Angular Resolution Principle for Coded-mask X-ray Imaging Beyond the Diffraction Limit of Single Pinhole
High angular resolution X-ray imaging is always demanded by astrophysics and solar physics, which can be realized by coded-mask imaging with very long mask-detector distance in principle. Previously the diffraction-interference effect has been thought to degrade coded-mask imaging performance dramatically at low energy end with very long maskdetector distance. In this work the diffraction-inter...
متن کاملGrid-enhanced X-ray coded aperture microscopy with polycapillary optics
Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10-100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imagin...
متن کاملPencil beam coded aperture x-ray scatter imaging
We use coded aperture x-ray scatter imaging to interrogate scattering targets with a pencil beam. Observations from a single x-ray exposure of a flat-panel scintillation detector are used to simultaneously determine the along-beam positions and momentum transfer profiles of two crystalline powders (NaCl and Al). The system operates with a 3 cm range resolution and a momentum transfer resolution...
متن کاملA Fourier-Based Algorithm for Modelling Aberrations in HETE-2’s Imaging System
The High-Energy Transient Explorer (HETE-2), launched in October 2000, is a satellite experiment dedicated to the study of γ-ray bursts in a very wide energy range from soft X-ray to γ-ray wavelengths. The intermediate X-ray range (2-30 keV) is covered by the Wide-field X-ray Monitor WXM, a coded aperture imager. In this article, an algorithm for reconstructing the positions of γ-ray bursts is ...
متن کامل