In order to realize the intelligent diagnosis of the electric pump and the motor working condition during the operation period of the electric pump well, an expert system based on fault tree and rete algorithm is realized. Through the analysis on the fault characteristics of the electric pump well, established the fault tree and knowledge base that support electric pump and motor working condition diagnosis, then combined with the rete algorithm based on production rule, which is used to obtain the diagnosis result of working condition, and gives the corresponding optimization suggestion. At last, based on the basic data and motor test data of electric pump well, the working conditions of 57 wells were diagnosed. The result shows that the diagnosis results are consistent with the practice, which improves the efficiency and accuracy of the working condition’s fault location.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Linguistic Rules Diagnosis of Failure in Centrifugal Pump for Use in Expert System

Operational failures in centrifuge pumps could be hydraulic or mechanical. However, most of these mechanical and hydraulic failures are connected cause of their operational nature and finding the right cause is due to considering numerous mechanical and hydraulic signs and parameters in pumps. On the other hand, due to non-linear and fluctuant behavior of pumps in the matter of time and not pre...

متن کامل

Development of Linguistic Rules Diagnosis of Failure in Centrifugal Pump for Use in Expert System

Operational failures in centrifuge pumps could be hydraulic or mechanical. However, most of these mechanical and hydraulic failures are connected cause of their operational nature and finding the right cause is due to considering numerous mechanical and hydraulic signs and parameters in pumps. On the other hand, due to non-linear and fluctuant behavior of pumps in the matter of time and not pre...

متن کامل

Augmented Reality System and Maintenance of Oil Pumps

Qualification of employees who operate technological processes directly influences the safety of production. However, the employees’’ qualification cannot completely exclude human factor. Today, there are many technologies that can minimize or eliminate human factor impact on production safety ensuring. The augmented reality technology is an example of this technology. Nowadays, the augmented r...

متن کامل

Determining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations

One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB ...

متن کامل

The parametric study of an electrical submersible pump rotary gas separator under two-phase flow condition

The performance of the electric submersible pump (ESP) significantly affected by Gas Void Fraction (GVF). Thus, using of a Rotary Gas Separator (RGS) is a suitable solution for this issue. The performance of the RGS is function of different parameters such as geometry of impeller, rotating speed, boundary conditions, media viscosity and GVF. In this study, the influences of GVF, viscosity, ...