Determination of moisture diffusion coefficient for oil-impregnated Kraft-paper insulation
نویسندگان
چکیده
Article history: Received 4 September 2012 Received in revised form 25 April 2013 Accepted 2 May 2013
منابع مشابه
Study of the Impact of Initial Moisture Content in Oil Impregnated Insulation Paper on Thermal Aging Rate of Condenser Bushing
This paper studied the impact of moisture on the correlated characteristics of the condenser bushings oil-paper insulation system. The oil-impregnated paper samples underwent accelerated thermal aging at 130 ̋C after preparation at different initial moisture contents (1%, 3%, 5% and 7%). All the samples were extracted periodically for the measurement of the moisture content, the degree of polym...
متن کاملOn the Feasibility of Using Poles Computed from Frequency Domain Spectroscopy to Assess Oil Impregnated Paper Insulation Conditions
Frequency Domain Spectroscopy (FDS) is an effective tool allowing assessing the condition of oil-paper insulation system in power equipment. However, results from these measurements are known to be greatly influenced by various parameters, including insulation aging, moisture content, and insulation geometry/volume, together with environmental condition such as temperature. In this contribution...
متن کاملDetermination of Moisture Content in Mass Impregnated Cable Insulation Using Low Frequency Dielectric Spectroscopy
The variations in the low frequency dielectric spectra of mass impregnated insulation depending on its moisture content have been investigated. For the calibration purposes a number of the impregnated paper samples was kept in the desiccators where different relative humidities were maintained. Thus obtained moisture content in the samples ranged from 1 % up to 6 %. The variations of the comple...
متن کاملEffect of Stress on Transformer Insulation
Power transformers use Kraft paper as insulation in the electrical windings present in the core, which is immersed in oil. In service, the temperature of the windings of core will go to 75C to 85C. If the transformer is over loaded, then the temperature can exceed upto 100°C causing the cellulose chains in the paper to cleave at an accelerated rate, which results in the degradation of mechanica...
متن کاملDevelopment of a Moisture-in-Solid-Insulation Sensor for Power Transformers
Moisture is an important variable that must be kept under control to guarantee a safe operation of power transformers. Because of the hydrophilic character of cellulose, water mainly remains in the solid insulation, while just a few parts per million are dissolved in oil. The distribution of moisture between paper and oil is not static, but varies depending on the insulation temperature, and th...