Nitrogen Dioxide Sterilization in Low-Resource Environments: A Feasibility Study
نویسندگان
چکیده
Access to sterilization is a critical need for global healthcare, as it is one of the prerequisites for safe surgical care. Lack of sterilization capability has driven up healthcare infection rates as well as limited access to healthcare, especially in low-resource environments. Sterilization technology has for the most part been static and none of the established sterilization methods has been so far successfully adapted for use in low-resource environments on a large scale. It is evident that healthcare facilities in low-resource settings require reliable, deployable, durable, affordable, easily operable sterilization equipment that can operate independently of scarce resources. Recently commercialized nitrogen dioxide (NO2) sterilization technology was analyzed and adapted into a form factor suitable for use in low-resource environments. Lab testing was conducted in microbiological testing facilities simulating low-resource environments and in accordance with the requirements of the international sterilization standard ANSI/AAMI/ISO 14937 to assess effectiveness of the device and process. The feasibility of a portable sterilizer based on nitrogen dioxide has been demonstrated, showing that sterilization of medical instruments can occur in a form factor suitable for use in low-resource environments. If developed and deployed, NO2 sterilization technology will have the twin benefits of reducing healthcare acquired infections and limiting a major constraint for access to surgical care on a global scale. Additional benefits are achieved in reducing costs and biohazard waste generated by current health care initiatives that rely primarily on disposable kits, increasing the effectiveness and outreach of these initiatives.
منابع مشابه
The baffling issues of Brugada electrocardiogram pattern for anaesthesiologist!
1. Rutala WA, Weber DJ. New disinfection and sterilization methods. Emerg Infect Dis. 2001;7(2):348-53. 2. Batista Neto S, Graziano KU, Padoveze MC, Kawagoe JY. The sterilization efficacy of reprocessed single use diathermy pencils. Rev Latino-Am Enfermagem. 2010;18(1):81-6. 3. Du C, Shang C, WangT. A portable plasma sterilizer. Plasma Chem Plasma Process 2017;37:77. 4. Sousa CS, Torres LM, Aze...
متن کاملDense CO2: An Innovative Method for Sterilization of Venous Catheters at Low Temperature
Venous catheters are important medical devices which are more and more employed in medical treatment. After use, they are currently not re-used, a practice which is very expensive due to their cost. For this reason it is very interesting to be able to set up a sterilizing technology that permit to re-use them without changing their physical properties and the microbial adhesion. The methods usu...
متن کاملModeling the Vapor – Liquid Equilibrium and Association of Nitrogen Dioxide / Dinitrogen Tetroxide and Its Mixtures with Carbon Dioxide
متن کامل
Feasibility of Supercritical Carbon Dioxide as a Drilling Fluid for Deep Underbalanced Drilling Operations
Feasibility of drilling with supercritical carbon dioxide to serve the needs of deep underbalanced drilling operations has been analyzed. A case study involving underbalanced drilling to access a depleted gas reservoir is used to illustrate the need for such a research. For this well, nitrogen was initially considered as the drilling fluid. Dry nitrogen, due to its low density, was unable to ge...