Is Endotoxemia in Stable Hemodialysis Patients an Artefact? Limitations of the Limulus Amebocyte Lysate Assay and Role of (1→3)-β-D Glucan
نویسندگان
چکیده
BACKGROUND Elevated blood endotoxin levels are frequently reported in the dialysis population and are strongly linked with inflammation, a major predictor of mortality. Virtually all studies have employed the Limulus Amoebocyte Lysate (LAL) assay to detect endotoxin. However this assay is not endotoxin-specific and can be activated by (1→3)-β-glucan (BG), a component of fungal cell walls leading to false positive signals. Very few studies have taken account of this. We examined the influence of BG-based activation of the LAL assay on the detection of endotoxemia in this setting. METHOD We measured plasma endotoxin levels in 50 hemodialysis patients with and without the use of BG-blocking buffers. These buffers inhibit BG activation of the LAL assay to ensure that any signal detected is endotoxin-specific. Blood samples were measured for BG, interleukin-6 (IL-6), tumor necrosis factor-alfa (TNF-α) to examine the association between endotoxin signals, BG and inflammation. RESULTS Endotoxin signals were detected in 50% of patients. On repeat measurement with a BG-blocking buffer, all detected endotoxin signals were extinguished. No patient had detectable endotoxemia. Plasma BG levels were significantly elevated in 58% of patients and were higher in those with detectable endotoxin signals using the LAL assay without BG-blocking buffers (78vs.54pg/mL;p<0.001). Endotoxin signal and BG levels did not correlate with levels of TNF-α or IL-6. CONCLUSION Use of the LAL assay for blood endotoxin detection in dialysis patients has its limitations due to high blood BG. Endotoxemia frequently reported in non-infected hemodialysis patients may be artefactual due to BG interference.
منابع مشابه
Outdoor (1→3)-β-D-glucan Levels and Related Climatic Factors
OBJECTIVES To evaluate the monthly variation in the airborne (1→3)-β-D-glucan level throughout one year and its relationship with climatic factors (temperature, relative humidity, wind speed, hours of daylight, cloud cover, and pollen counts). METHODS A total of 106 samples were collected using a two-stage cyclone sampler at five outdoor sampling locations (on top of 5 university buildings). ...
متن کاملEndotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...
متن کاملEndotoxemia: methods of detection and clinical correlates.
As an assay for endotoxin, the Limulus amebocyte lysate assay has several desirable properties: sensitivity, specificity, and potential for adaptation to a quantitative format. Several modifications have been developed to enhance its potential for clinical application. The modifications that allow quantitative measurement of endotoxin and also improve its application to blood samples are descri...
متن کاملConcordance of endotoxemia with gram-negative bacteremia in patients with gram-negative sepsis: a meta-analysis.
The Limulus amebocyte lysate (LAL) assay is a sensitive method for detecting endotoxin. Using gram-negative (GN) bacteremia as the basis for comparison, concordance with endotoxemia in 45 studies could be expressed as an odds ratio. Calculation of summary odds ratios by the Mantel-Haenszel-Peto method indicated that the concordance of the results was no higher by the chromogenic LAL assay than ...
متن کاملComparison of Two Analytical Methods for Detecting (1-3)- -D-Glucan in Pure Fungal Cultures and in Home Dust Samples
There are two methods available for the analysis of (1-3)-D-glucan: the Limulus Amebocyte Lysate assay (LAL) and the inhibition Enzyme Immunoassay (EIA). The aim of this study was to compare the accuracy and specificity of these two methods in detecting eight alpha and beta-glucan standards, and their sensitivity for the analysis of (1-3)D-glucan content of common indoor fungal species and indo...
متن کامل