The Teleoperator with Wave Impedance and Environment Impedance Matched ⋆

نویسندگان

  • Lingyan Hu
  • Yong Xin
  • Shaoping Xu
  • Yuanchun Xu
  • Panlong Gao
  • Peng Wan
چکیده

The wave impedance and the environment impedance are important for the wave-variable based teleoperator. It is difficult to get good performance when the parameters are not proper. The paper addresses how to design the wave based teleoperator when working environment undergoes changed. It is concluded that wave impedance should match environment impedance by discussing how wave impedance and environment impedance influence performance of the system. An teleoperator with wave impedance changing with environment impedance is designed to keep good trajectory tracking when working environment impedance undergoes changed. The experiment results show the trajectory performance and stability are good when wave impedance matches environment impedance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Position Controlled Telepresence Systems with Time Delay

This paper discusses combined position and force control of telepresence systems with force feedback and time delay. Standard architectures use velocity/force control and well known passivity arguments. Disadvantageously, then the positions of the Human System Interface (HSI) and the teleoperator diverge in presence of disturbances, deteriorating transparency. In this paper a new method for imp...

متن کامل

Study of Teleoperation Using Realtime Communication Network Emulation

The stability and performance of telepresence systems with kinesthetic (force) feedback operated via a communication network mainly depends on the quality (delay, bandwidth) of communication. The combined position/force control of teleoperation system with time delay using impedance matching filters to achieve robust passivity for the teleoperator/ environment and transparency is discussed. The...

متن کامل

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Impedance controller design of Internet-based teleoperation using absolute stability concept

Relationships between impedance parameters and scaling factors are derived using absolute stability and passivity. For this, the teleoperation system is represented as a two-port model with a hybrid matrix. Design procedure of the impedance parameters for the absolute stability of the teleoperator under the time delay is proposed. The validity of the proposed control scheme is demonstrated by e...

متن کامل

Comparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis

Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013