Quality control system for blood irradiation using a teletherapy unit.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES Irradiation of whole blood and blood components before transfusion is currently the only accepted methodology to prevent transfusion-associated graft-vs.-host disease. In the present work, we developed an automated system for blood bag storage during irradiation, using a teletherapy unit. MATERIALS AND METHODS A device with two thermal compartments was constructed in acrylic and foam, for the storage of blood bags during irradiation. An automatic acquisition system, coupled with an amplifier and a thermal-sensitive probe, were developed to check blood temperature during irradiation. A polystyrene phantom was constructed to simulate the volume of blood routinely irradiated. The dose distribution was measured in the phantom using thermoluminescent dosimeters and represented in terms of isodose curves. RESULTS The thermal device kept the blood temperature below 6 degrees C for more than 2 h. Our system allowed the simultaneous irradiation of two different blood components while maintaining a constant temperature. The temperature monitoring system remained invariant (0.2 degrees C) over the whole irradiation interval. Phantom dosimetric results showed a homogeneous dose distribution when the phantom was irradiated, using rotational fields with a 2 r.p.m. frequency. CONCLUSIONS The methodology developed in the present work provides appropriate storage conditions during irradiation of both red blood cells and platelet blood components using a teletherapy unit.
منابع مشابه
Quality control of blood irradiation with a teletherapy unit: damage to stored red blood cells after cobalt-60 gamma irradiation.
BACKGROUND Previous publications have documented the damage caused to red blood cells (RBCs) irradiated with X-rays produced by a linear accelerator and with gamma rays derived from a 137Cs source. The biologic effects on RBCs of gamma rays from a 60Co source, however, have not been characterized. STUDY DESIGN AND METHODS This study investigated the effect of 3000 and 4000 cGy on the in vitro...
متن کاملTotal body irradiation with a reconditioned cobalt teletherapy unit
While the current trend in radiotherapy is to replace cobalt teletherapy units with more versatile and technologically advanced linear accelerators, there remain some useful applications for older cobalt units. The expansion of our radiotherapy department involved the decommissioning of an isocentric cobalt teletherapy unit and the replacement of a column-mounted 4-MV LINAC that has been used f...
متن کاملPrevention of Transfusion-Associated Graft-versus-Host Disease by Irradiation: Technical Aspect of a New Ferrous Sulphate Dosimetric System
Irradiation of whole blood and blood components before transfusion is currently the only accepted method to prevent Transfusion-Associated Graft-Versus-Host-Disease (TA-GVHD). However, choosing the appropriate technique to determine the dosimetric parameters associated with blood irradiation remains an issue. We propose a dosimetric system based on the standard Fricke Xylenol Gel (FXG) dosimete...
متن کاملMULTICRITERION SYNTHESIS OF INTELLIGENT CONTROL SYSTEMS OF GENERATING UNIT OF NUCLEAR POWER STATION
The paper is devoted to solution of some problems in nuclear power station generating unit intellectual control systems using genetic algorithms on the basis of control system model development, optimizations methods of their direct quality indices and improved integral quadratic estimates. Some mathematical vector models were obtained for control system multicriterion quality indices with due ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vox sanguinis
دوره 86 2 شماره
صفحات -
تاریخ انتشار 2004