Dummy source digitization algorithm for reconstruction of flexible brachytherapy catheters with biplane images

نویسنده

  • Jenö Pálvölgyi
چکیده

PURPOSE The traditional brachytherapy catheter reconstruction with biplane images is based on digitizing radio-opaque markers with a pointing device on a film or on a screen. An algorithm to automate digitization of radio-opaque marker coordinates on biplane images is presented. MATERIAL AND METHODS To obtain the marker coordinates in a proper sequence, instead of usual pair of reconstruction images, series of images were taken with insertion of radio-opaque markers consecutively into the catheters. The images were pre-processed to suppress the shield of anatomic structures. The determination of the marker coordinates is based on the detection of characteristic high gradient variation in pre-processed image profiles. The method was tested with six endometrial insertions performed with Simon-Norman catheters using our version of Heyman packing. RESULTS 28 catheters of six treatment fractions were digitized, typically 10 markers per catheter. To obtain the marker coordinates, adjustment of two threshold levels on the pre-processed images were needed. The coordinates of the radio-opaque markers on the biplane projection images were obtained without positive or negative artefact. CONCLUSIONS THE DUMMY SOURCE COORDINATES ON THE BIPLANE IMAGES WERE DIGITIZED IN A PROPER SEQUENCE: from the catheters' tip towards the end of the catheters. After the three-dimensional reconstruction of the catheters from the digitized coordinates, the geometry file was imported by the brachytherapy planning system for dose calculation. The method has the advantage to eliminate manual digitization of the dummy sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources

Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet s...

متن کامل

Comparison and verification of the reconstruction method of the catheters for interstitial brachytherapy

PURPOSE 1. Comparison and verification of accuracy of the implant reconstruction method based on images from IBU and CT. 2. Estimation of influence of the implant reconstruction method on dose disposition in selected reference points. MATERIAL AND METHODS Paraffin-wax phantom with three catheters, central marker and control point were prepared. IBU unit were used for obtaining two series of i...

متن کامل

Pre-treatment 2D Scout Verification Tolerances and Dosimetry Effects on OARs for the Cylinder High Dose Rate Brachytherapy Treatment of Vaginal Cuff Cancer

Purposes: to statistically find out the achievable and practical pre-treatment verification tolerances for HDR (high dose rate) cylinder treatment using scout AP (anterior and posterior) /LAT (lateral) images and the corresponding organs at risk dosimetry effects. Materials and Methods: Five previously treated vaginal cuff cancer patients were randomly selected. All of the patients had prescrip...

متن کامل

Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer.

BACKGROUND AND PURPOSE To elaborate a method for applicator reconstruction for MRI-based brachytherapy for cervical cancer. MATERIALS AND METHODS Custom-made plastic catheters with a copper sulphate solution were made for insertion in the source channels of MR-CT compatible applicators: plastic and titanium tandem ring applicators, and titanium needles. The applicators were CT and MR scanned ...

متن کامل

Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies*

OBJECTIVE To identify a contrast material that could be used as a dummy marker for magnetic resonance imaging. MATERIALS AND METHODS Magnetic resonance images were acquired with six different catheter-filling materials-water, glucose 50%, saline, olive oil, glycerin, and copper sulfate (CuSO4) water solution (2.08 g/L)-inserted into compatible computed tomography/magnetic resonance imaging ri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014