GigaFRoST: the gigabit fast readout system for tomography

نویسندگان

  • Rajmund Mokso
  • Christian M. Schlepütz
  • Gerd Theidel
  • Heiner Billich
  • Elmar Schmid
  • Tine Celcer
  • Gordan Mikuljan
  • Leonardo Sala
  • Federica Marone
  • Nick Schlumpf
  • Marco Stampanoni
چکیده

Owing to recent developments in CMOS technology, it is now possible to exploit tomographic microscopy at third-generation synchrotron facilities with unprecedented speeds. Despite this rapid technical progress, one crucial limitation for the investigation of realistic dynamic systems has remained: a generally short total acquisition time at high frame rates due to the limited internal memory of available detectors. To address and solve this shortcoming, a new detection and readout system, coined GigaFRoST, has been developed based on a commercial CMOS sensor, acquiring and streaming data continuously at 7.7 GB s-1 directly to a dedicated backend server. This architecture allows for dynamic data pre-processing as well as data reduction, an increasingly indispensable step considering the vast amounts of data acquired in typical fast tomographic experiments at synchrotron beamlines (up to several tens of TByte per day of raw data).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and developing an in-house CCD based optical CT scanner for gel dosimetry

Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Closed-Loop Compensation of the Quadrature Error in MEMS Vibratory Gyroscopes

In this paper, a simple but effective method for compensation of the quadrature error in MEMS vibratory gyroscope is provided. The proposed method does not require any change in the sensor structure, or additional circuit in the feedback path. The mathematical relations of the proposed feedback readout system were analyzed and the proposed solution assures good rejection capabilities. Based on ...

متن کامل

Global Tracking Unit for ALICE TRD

The ALICE TRD Detector employs 1080 optical links for data readout. The FEE chips (TRAP [1]) form a readout tree running at 8 bit 120 MHz double data rate. The tracklet and raw data are sent over the Optical Readout Interface (ORI) at 2.5 Gbit/s. The Global Tracking Unit (GTU) serves as data receiver and fast track finder and contributes to the L1 trigger decision. Finally, after L2 accept the ...

متن کامل

Testing Ethernet Networks for the ATLAS Data Collection System

This paper reports recent work on Ethernet traffic generation and analysis. We use Gigabit Ethernet NICs running customized embedded software and custom-built 32-port Fast Ethernet boards based on FPGAs to study the behavior of large Ethernet networks. The traffic generation software is able to accommodate many traffic distributions with the ultimate goal of generating traffic that resembles th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2017