Sandwich Wound Closure Reduces the Risk of Cerebrospinal Fluid Leaks in Posterior Fossa Surgery

نویسندگان

  • Verena Heymanns
  • Abidemi W. Oseni
  • Ameer Alyeldien
  • Homajoun Maslehaty
  • Richard Parvin
  • Martin Scholz
  • Athanasios K. Petridis
چکیده

Posterior fossa surgery is demanding and hides a significant number of obstacles starting from the approach to the wound closure. The risk of cerebrospinal fluid (CSF) leakage in posterior fossa surgery given in the literature is around 8%. The present study aims to introduce a sandwich closure of the dura in posterior fossa surgery, which reduces significantly the number of CSF leaks (3.8%) in the patients treated in our department. Three hundred and ten patients treated in our hospital in the years 2009-2013 for posterior fossa pathologies were retrospectively evaluated. The dura closure method was as following: lyophilized dura put under the dura and sealed with fibrin glue and sutures, dura adapting stitches, TachoSil® (Takeda Pharma A/S, Roskilde, Denmark), Gelfoam® (Pfizer Inc., New York, NY, USA) and polymethylmethacrylate (osteoclastic craniotomy). The incidence of postsurgical complications associated with the dural closure like CSF leakage, infections, bleeding is evaluated. Only 3.8% of patients developed CSF leakage and only 0.5% needed a second surgery for CSF leakage closure. Two percent had a cerebellar bleeding with no need for re-operation and 3% had a wound infection treated with antibiotics. The sandwich wound closure we are applying for posterior fossa surgery in our patients correlates with a significant reduction of CSF leaks compared to the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two alternative dural sealing techniques in posterior fossa surgery: (Polylactide-co-glycolide) self-adhesive resorbable membrane versus polyethylene glycol hydrogel

BACKGROUND Post-operative cerebrospinal fluid (CSF) leak in posterior fossa surgery remains a significant source of morbidity. TissuePatchDural (TPD), a novel impermeable adhesive membrane, was used to reinforce dural closure. A comparison with one of the most commonly used dural sealing devices, DuraSeal, has been made. METHODS A retrospective, single-center study was conducted on 161 patien...

متن کامل

Time-sparing and effective procedure for dural closure in the posterior fossa using a vicryl mesh (Ethisorb).

INTRODUCTION Dural defects and cerebrospinal fluid (CSF) leaks are a common problem following posterior fossa surgery. The management includes either nonoperative management (e.g. external lumbar drainage) or surgical re-exploration. OBJECTIVES We present our surgical, clinical and histopathological experience of dural closure in the posterior fossa. In order to avoid CSF leaks we developed a...

متن کامل

Evaluation of Non-Watertight Dural Reconstruction with Collagen Matrix Onlay Graft in Posterior Fossa Surgery

OBJECTIVE Many surgeons advocate for watertight dural reconstruction after posterior fossa surgery given the significant risk of cerebrospinal fluid (CSF) leak. Little evidence exists for posterior fossa dural reconstruction utilizing monolayer collagen matrix onlay graft in a non-watertight fashion. Our objective was to report the results of using collagen matrix in a non-watertight fashion fo...

متن کامل

Management of Cerebrospinal Fluid Leak following Posterior Cranial Fossa Surgery

OBJECTIVE Cerebrospinal fluid leakage remains a significant cause of morbidity following posterior fossa surgery, and its treatment remains a difficult problem. The aim of the study was to propose a treatment algorithm for its management. METHODS A retrospective, single-center study was conducted on 147 patients who underwent elective posterior fossa surgery for a variety of diseases . Patien...

متن کامل

Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report

A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016