Ultrasonic sound as an indicator of acute pain in laboratory mice.
نویسندگان
چکیده
In response to pain, mice may vocalize at frequencies above the range of human hearing (greater than 20 kHz). To determine whether an ultrasonic recording system is a reliable tool for assessing acute pain, we measured audible and ultrasonic vocalization in mice subjected to either nonpainful or potentially painful procedures performed routinely in animal facilities. Data were collected from 109 weanling mice (Mus musculus; B6, 129S6-Stab 5b) scheduled for 2 potentially painful procedures: DNA testing by tail snip and identification by ear notching. The mice each were assigned randomly to 1 of 4 groups: 1) actual tail snip, 2) sham tail snip, 3) actual ear notch, or 4) sham ear notch. Vocalizations during the treatments were recorded with an ultrasonic recorder. Most mice (65%; n = 55) demonstrated no vocal response to the potentially painful procedures. More mice that received actual tail snips produced audible sounds (11 of 29 mice) than did those that underwent sham tail snips (0 of 30 mice). In addition, audible vocalizations occurred more frequently during ear notch procedures (8 of 26 mice) than during sham ear-notch manipulations (2 of 24 mice). For all 20 of the mice that produced ultrasonic vocalizations, these calls were accompanied by simultaneous audible components. We conclude that ultrasonic vocalizations do not provide any more information than do audible vocalizations for assessing responses to potentially painful procedures. In addition, because many mice made no sound at all after a potentially painful stimulus, vocalizations generally are not good metrics of acute pain in laboratory mice. Alternatively, the lack of vocalizations in many of the mice may suggest that tail snipping and ear notching are not particularly painful procedures for most of these mice.
منابع مشابه
Design and fabrication of an ultrasonic thermoacoustic generator using metal nanocoatings (Research Article)
In this paper, we design, simulate, and build an ultrasonic heat generator. In thermoacoustics, heat generated by the passage of alternating current through a thin conductor produces a sound wave. In this method, unlike other methods of sound production, moving parts are not used to vibrate air molecules, and as a result, the frequency response of these generators is flatter than other sound ge...
متن کاملTypes and functions of ultrasonic vocalizations in laboratory rats and mice.
Many laboratory rodents emit ultrasonic vocalizations. The purpose of this review is to highlight the types and functions of ultrasonic vocalizations emitted by laboratory rats and mice. Rats emit 3 types of ultrasonic vocalizations, depending on the animal's age, its environmental conditions, and its affective state. Rat pups emit a 40-kHz vocalization when they are separated from their mother...
متن کاملOpiate System Mediate the Antinociceptive Effects of Coriandrum sativum in Mice
Our previous study showed that Coriandrum sativum (CS) has antinociceptive effects, but the mechanisms that mediate this effect are not clear. The present study was designed to test the role of opiate system in the antinociceptive effects of CS on acute and chronic pain in mice using Hot Plate (HP), Tail Flick (TF) and Formalin (FT) tests and also to compare its effect with dexamethasone (DE...
متن کاملOpiate System Mediate the Antinociceptive Effects of Coriandrum sativum in Mice
Our previous study showed that Coriandrum sativum (CS) has antinociceptive effects, but the mechanisms that mediate this effect are not clear. The present study was designed to test the role of opiate system in the antinociceptive effects of CS on acute and chronic pain in mice using Hot Plate (HP), Tail Flick (TF) and Formalin (FT) tests and also to compare its effect with dexamethasone (DE...
متن کاملInjury to skeletal muscle of mice following acute and sub-acute pregabalin exposure
Objective(s): Pregabalin (PGB) is a new antiepileptic drug that has received FDA approval for patient who suffers from central neuropathic pain, partial seizures, generalized anxiety disorder, fibromyalgia and sleep disorders. This study was undertaken to evaluate the possible adverse effects of PGB on the muscular system of mice. Materials and Methods: To evaluate the effect of PGB on skeletal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Association for Laboratory Animal Science : JAALAS
دوره 47 1 شماره
صفحات -
تاریخ انتشار 2008