Aerosol characterization and pulmonary responses in rats after short-term inhalation of fumes generated during resistance spot welding of galvanized steel

نویسندگان

  • James M. Antonini
  • Aliakbar Afshari
  • Terence G. Meighan
  • Walter McKinney
  • Mark Jackson
  • Diane Schwegler-Berry
  • Dru A. Burns
  • Ryan F. LeBouf
  • Bean T. Chen
  • Mohammad Shoeb
  • Patti C. Zeidler-Erdely
چکیده

Resistance spot welding is a common process to join metals in the automotive industry. Adhesives are often used as sealers to seams of metals that are joined. Anti-spatter compounds sometimes are sprayed onto metals to be welded to improve the weldability. Spot welding produces complex aerosols composed of metal and volatile compounds (VOCs) which can cause lung disease in workers. Male Sprague-Dawley rats (n = 12/treatment group) were exposed by inhalation to 25 mg/m3 of aerosol for 4 h/day × 8 days during spot welding of galvanized zinc (Zn)-coated steel in the presence or absence of a glue or anti-spatter spray. Controls were exposed to filtered air. Particle size distribution and chemical composition of the generated aerosol were determined. At 1 and 7 days after exposure, bronchoalveolar lavage (BAL) was performed to assess lung toxicity. The generated particles mostly were in the submicron size range with a significant number of nanometer-sized particles formed. The primary metals present in the fumes were Fe (72.5%) and Zn (26.3%). The addition of the anti-spatter spray and glue did affect particle size distribution when spot welding galvanized steel, whereas they had no effect on metal composition. Multiple VOCs (e.g., methyl methacrylate, acetaldehyde, ethanol, acetone, benzene, xylene) were identified when spot welding using either the glue or the anti-spatter spray that were not present when welding alone. Markers of lung injury (BAL lactate dehydrogenase) and inflammation (total BAL cells/neutrophils and cytokines/chemokines) were significantly elevated compared to controls 1 day after exposure to the spot welding fumes. The elevated pulmonary response was transient as lung toxicity mostly returned to control values by 7 days. The VOCs or the concentrations that they were generated during the animal exposures had no measurable effect on the pulmonary responses. Inhalation of galvanized spot welding fumes caused acute lung toxicity most likely due to the short-term exposure of particles that contain Zn.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recovery from welding-fume-exposure-induced lung fibrosis and pulmonary function changes in sprague dawley rats.

Welder's pneumoconiosis has generally been determined as benign based on the absence of pulmonary function abnormalities in welders with marked radiographic abnormalities. Yet, there have also been several reports on welders with respiratory symptoms, indicating lung function impairment, X-ray abnormalities, and extensive fibrosis. Accordingly, this study attempted to investigate the inflammato...

متن کامل

Effect of short-term stainless steel welding fume inhalation exposure on lung inflammation, injury, and defense responses in rats.

Many welders have experienced bronchitis, metal fume fever, lung function changes, and an increase in the incidence of lung infection. Questions remain regarding the possible mechanisms associated with the potential pulmonary effects of welding fume exposure. The objective was to assess the early effects of stainless steel (SS) welding fume inhalation on lung injury, inflammation, and defense r...

متن کامل

Dissolution of stainless steel welding fumes in the rat lung: an x ray microanalytical study.

The dissolution of stainless steel welding fumes produced by manual metal arc (MMA) and metal inert gas (MIG) techniques was studied by transmission electron microscopy and quantitative x ray microanalysis in the lungs of rats after inhalation exposure. Rats exposed to stainless steel fumes generated by MMA were found to have two particle populations of different behaviour in their lung tissue....

متن کامل

Construction of an exposure chamber for animals and its use for inhalation exposure to welding fumes and gases.

An inhalation exposure system, consisting of an inhalation chamber and an generating and feeding device for welding fumes and gases with a welding robot, was constructed and examined for its application to experimental toxicology for ventilatory responses of conscious rats to welding fumes and gases. The exposure system allowed an inhalation of fresh welding fumes and gases, and could supply ai...

متن کامل

Health effects of welding.

Many of the epidemiology studies performed are difficult to compare because of differences in worker populations, industrial settings, welding techniques, duration of exposure, and other occupational exposures besides welding fumes. Some studies were conducted in carefully controlled work environments, others during actual workplace conditions, and some in laboratories. Epidemiology studies hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017