The use of ultrasound for placement of intravenous catheters.

نویسندگان

  • Hector Aponte
  • Said Acosta
  • Donald Rigamonti
  • Barbara Sylvia
  • Paul Austin
  • Timothy Samolitis
چکیده

Ultrasound has been used to aid cannulation of veins of the neck, chest, antecubital fossa, and femoral vein. This investigation compared the traditional method of peripheral intravenous (IV) cannulation of veins of the hands and forearms with ultrasound-guided IV cannulation of these veins. After obtaining institutional review board approval and written informed consent, 35 adult subjects with a history or suspicion of difficult IV cannulation were prospectively enrolled with 16 subjects randomly assigned to the traditional group and 19 to the ultrasound group. Time taken for successful venous cannulation and number of attempts between the groups were compared using a Mann-Whitney U test. The number of subjects in whom IV cannulation was successful on the first attempt was compared between the groups using the Fisher exact test. No significant differences were noted between groups in demographics, time to successful cannulation, number of attempts, and number of subjects in whom IV cannulation was successful on the first attempt. Ultrasound was as efficacious as the traditional method of IV cannulation in this subset of patients. Future investigations should examine the efficacy of the ultrasound-guided technique of IV cannulation of these veins in patients in whom the traditional method failed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

9 Ultrasound Guided Vascular Access

Vascular access is an important procedure for clinicians to master. Chronic medical conditions, intravenous drug use, and obesity can all make placements of vascular catheters in central and peripheral veins challenging and time-consuming. External landmarks have traditionally guided the placement of the needle for the performance of central venous catheterization. The proximity of such structu...

متن کامل

Comparison of Dwell-Times of Two Commonly Placed Peripheral Intravenous Catheters: Traditional vs. Ultrasound-Guided

Introduction: Because establishing venous access in patients can be difficult and time consuming, the use of ultrasound to guide the insertion of peripheral intravenous catheters has become more common. Anecdotal evidence indicates ultrasound-guided catheter insertion may result in decreased catheter survival in the vein (dwell-time), but there is little evidence to support this observation. Th...

متن کامل

بررسی زمان ماندگاری کاتترهای داخل وریدی با میزان ابتلاء به فلبیت سطحی در بیماران بستری

Introduction & Objective: One of the most usual methods for access to blood vessels are intravenous catheters, which can cause some complications, therefore prevention of them is one of the most important medical goals. This study was performed to determining the incidence of superficial phlebitis with shelf life of intravenous catheters in hospitalized patients at Mobasher Kashani hospital of ...

متن کامل

Complications of Peripheral Intravenous Catheters During 72 Hours After Insertion

Introduction: Peripheral Intravenous catheterization is the most commonly used invasive treatment method in patients admitted to the hospitals, but it has some complications. The indwell time of catheter is one of the factors associated with the occurrence of complications, especially phlebitis. In spite of the instructions for replacing the catheters after 72 hours, sometimes the complications...

متن کامل

Real-time ultrasound detection of correct intravenous placement of central venous catheters after ultrasound cannulation.

Ultrasound-guided technique for central venous catheterization has been a widely developed procedure during the last decade. Nowadays, it is a common technique in the anaesthesiologist’s clinical practice. During the last six years, we usually have carried out central venous catheterization using the ultrasound-guided technique in our hospital. Moreover, we use to check correct intravenous plac...

متن کامل

Letters: Effect of Ultrasound-Guided Placement of Difficult-to-Place Peripheral Venous Catheters: A Prospective Study of a Training Program for Nurse Anesthetists.

Patients with difficult intravenous access (DIVA) often experience discomfort because of failed attempts to place peripheral venous catheters (PVCs); however, ultrasound guidance may improve this problem with catheter placement. The aim of this study was to evaluate the use of ultrasound when operated by nurse anesthetists for these patients. This prospective observational study with a pre/post...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AANA journal

دوره 75 3  شماره 

صفحات  -

تاریخ انتشار 2007