Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine.
نویسندگان
چکیده
The determination of blood flow, i.e. cardiac output, is an integral part of haemodynamic monitoring. This is a review on noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. We present the underlying principles and validation data of the following technologies: thoracic electrical bioimpedance, thoracic bioreactance, vascular unloading technique, pulse wave transit time, and radial artery applanation tonometry. According to clinical studies, these technologies are capable of providing cardiac output readings noninvasively and continuously. They, therefore, might prove to be innovative tools for the assessment of advanced haemodynamic variables at the bedside. However, for most technologies there are conflicting data regarding the measurement performance in comparison with reference methods for cardiac output assessment. In addition, each of the reviewed technology has its own limitations regarding applicability in the clinical setting. In validation studies comparing cardiac output measurements using these noninvasive technologies in comparison with a criterion standard method, it is crucial to correctly apply statistical methods for the assessment of a technology's accuracy, precision, and trending capability. Uniform definitions for 'clinically acceptable agreement' between innovative noninvasive cardiac output monitoring systems and criterion standard methods are currently missing. Further research must aim to further develop the different technologies for noninvasive continuous cardiac output determination with regard to signal recording, signal processing, and clinical applicability.
منابع مشابه
Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?
Transesophageal echocardiography offers a noninvasive technique for the continuous monitoring of cardiac performance. The combination of 2-dimensional echocardiography and Doppler velocitometry provide assessment of cardiac anatomy, valve function and, ventricular loading conditions. Although transesophageal echocardiography has become accepted for perioperative monitoring, it is typically used...
متن کاملمانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری
Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملNoninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
BACKGROUND Monitoring of cardiac output and blood pressure are standard procedures in critical care medicine. Traditionally, invasive techniques like pulmonary artery catheter (PAC) and arterial catheters are widely used. Invasiveness bears many risks of deleterious complications. Therefore, a noninvasive reliable cardiac output (CO) and blood pressure monitoring system could improve the safety...
متن کاملContinuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis.
We present an evaluation of a novel technique for continuous (i.e., automatic) monitoring of relative cardiac output (CO) changes by long time interval analysis of a peripheral arterial blood pressure (ABP) waveform in humans. We specifically tested the mathematical analysis technique based on existing invasive and noninvasive hemodynamic data sets. With the former data set, we compared the app...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 114 4 شماره
صفحات -
تاریخ انتشار 2015