• Porous Titanium Particles in Cemented Impaction Grafting Hip Revision Arthroplasty: Pre-Clinical Results
ثبت نشده
چکیده
Introduction: Bone impaction grafting (BIG) is a surgical technique for the restoration of bone stock loss in revision total hip arthroplasty (rTHA) by impaction of allograft bone particles (BoP) into the bony defect. BoP are considered to be the gold standard, although many alternative materials have been developed, most of them being ceramic based. Important properties of these synthetic materials are surgical handling characteristics (impactability) and primary stability of the reconstruction. Furthermore, optimal porosity of reconstructive materials should combine limited cement penetration with long term stabilization by ingrowth of bone tissue. Previous studies showed that porous biphasic bioceramic particles (CeP) have to be mixed with bone grafts to limit cement penetration and to prevent pulverization during impaction. In order to create a full bone graft substitute for impaction grafting, a more deformable material was chosen to overcome the mechanical limitations of CeP. The goal of a series of in-vitro and in-vivo experiments was to assess the suitability of porous titanium particles (TiP) for application as a full bone graft substitute to be used in rTHA. Methods: In-vitro: Impactability and graft layer elastic properties after standardized impaction were studied in a confined compression chamber model with TiP (commercially pure titanium; density before impaction 0.5 g/ml; Fondel Medical BV, Rotterdam, The Netherlands), CeP and BoP. Realistic cemented in-vitro acetabular reconstructions (n=8) (Sawbones Europe, Malmö, Sweden; AAOS type 2 defects 60 mm; Exeter Contemporary cup, Stryker Orthopaedics, Exeter, UK) were made with TiP and with BoP to evaluate handling and cement penetration and to measure initial migration, rotation, and shear force resistance with a servo-hydraulic MTS machine and radiostereometric analysis (RSA). Realistic in-vitro femoral TiP reconstructions (n=7) (Sawbones Europe, Malmö, Sweden) were used to evaluate the applicability in the femur. Subsidence was measured during prolonged cyclic loading (300.000 loading cycles) and potential micro-particles that were released from the graft layer due to impaction or loading were analyzed using laser diffraction techniques (Malvern Mastersizer 2000, Malvern Instruments Ltd, Malvern, UK). In-vivo: Mature Dutch milk goats (Capra Hircus Sanus) with a mean body weight of 55 kg were used for all in-vivo experiments and all procedures were approved by the Animal Ethics Committee of the University of Nijmegen, The Netherlands. TiP (with or without a bioceramic coating) were tested under unloaded conditions in a femoral condyl study (n=12) and compared with BoP. To test TiP under realistic and loaded in-vivo conditions, acetabular defects (AAOS type 3 defect, repaired with a wire mesh, n=10) were reconstructed with impacted TiP acting as a full bone graft substitute in combination with a cemented total hip prosthesis (custom downsized contemporary cup, doubletapered polished Exeter sheep stem, Stryker Benoist, Girard, France). Blood samples were taken throughout the experiment to assess the release of Ti-ions into the blood. Goats were killed after fifteen weeks for histological analysis. Statistical analysis: Multivariable analysis of variance (alfa level 0.05) was used to study differences between groups or differences in time. Results are expressed as mean ± standard deviation. Results: In-vitro: The confined compression chamber test showed that TiP were more deformable than BoP. TiP created an entangled graft layer and did not fracture whereas CeP were pulverized during impaction. The elastic modulus of the graft was lower in TiP specimens than in CeP specimens but higher than in BoP specimens. Acetabular in-vitro testing showed that TiP stick together well during impaction (density of impacted TiP: 1.1 g/ml). Bone cement intrusion was found about 1.0 mm deeper in BoP graft layers than in TiP graft layers (p<0.02). TiP reconstructions showed better primary stability. Cup migration and rotation were about three times larger in BoP reconstructions than in TiP reconstructions (p<0.01) and shear force resistance was about four times larger in TiP reconstructions compared to BoP reconstructions (lever-out moment 12±4 Nm respectively 56±12 Nm, p<0.001). Good primary stability and limited cement penetration were reproduced in realistic in-vitro femoral reconstructions (density of impacted TiP: 1.1 g/ml). Average subsidence rates of the stem relative to the bone were low and reproducible (0.59 mm ± 0.41 mm after 300,000 loading cycles) and much smaller than subsidence seen in femoral bone impaction grafting [1]. Impaction generated 1.3 mg titanium particles per gram TiP, with a particle diameter range of 0.7-2000 μm and a trimodal size distribution (particle diameter at peak volume: 11 μm respectively 33 μm respectively 380 μm). The amount of particles collected at the end of loading was too small for analysis by laser diffraction. In-vivo: a thin bioceramic coating (10-40 μm) increased osteoconduction of impacted TiP. Bone ingrowth speed and distance were comparable between coated TiP and BoP. Cemented acetabular revision arthroplasty in goats (with 5-10g TiP) reproduced the findings of in-vitro and in-vivo studies: despite the limited penetration depth of the cement (408±309 μm) reconstructions were stable both at the cement-TiP interface and at the TiP-bone interface (Fig. 1). Two failures occurred at the cup-cement interface without affecting the TiP layer or gait of the goats. As a result these failures were unnoticed until post-mortem retrieval. Reconstructive layers of TiP had a mean thickness of 4479±566 μm (Fig. 1). Bone ingrowth occurred early (within four weeks) and was also present in very small TiP pores (Fig. 2, pink staining). Mean bone ingrowth distance after fifteen weeks was 2824±837 μm. A thin fibrous tissue interface with a mean thickness of 91±110 μm separated the cement from the TiP. After reconstructions with BoP in the same model this interface is ca 1 mm thick. Serum titanium concentrations increased gradually on a logarithmic scale from 0.60 ± 0.28 parts per billion (ppb) before operation to 1.06 ± 0.70 ppb at the end of the study (p=0.18).
منابع مشابه
In Vitro Testing of Femoral Impaction Grafting With Porous Titanium Particles: A Pilot Study
The disadvantages of allografts to restore femoral bone defects during revision hip surgery have led to the search for alternative materials. We investigated the feasibility of using porous titanium particles and posed the following questions: (1) Is it possible to create a high-quality femoral graft of porous titanium particles in terms of graft thickness, cement thickness, and cement penetrat...
متن کاملImpaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute
BACKGROUND AND PURPOSE One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous cerami...
متن کاملCancellous impaction grafting in femoral revision THA.
Options in the management of the deficient femur during revision hip arthroplasty include cemented or cementless fixation. The results with cemented femoral revision have not been historically successful. While the use of extensively coated implants in revision total hip arthroplasty has been more uniformly excellent, issues, such as thigh pain, stress shielding, and lack of bone stock restorat...
متن کاملPorous titanium particles for acetabular reconstruction in total hip replacement show extensive bony armoring after 15 weeks
BACKGROUND AND PURPOSE The bone impaction grafting technique restores bone defects in total hip replacement. Porous titanium particles (TiPs) are deformable, like bone particles, and offer better primary stability. We addressed the following questions in this animal study: are impacted TiPs osteoconductive under loaded conditions; do released micro-particles accelerate wear; and are systemic ti...
متن کاملImpaction Grafting for Revision Total Hip Arthroplasty
Impaction grafting for revision total hip arthroplasty is increasingly being used in cases complicated by substantial bone loss. Many techniques using cemented and noncemented designs with or without bone graft have had unpredictable outcomes and are the source of continuing debate. This new technique uses morselized allograft, impacted into a constrained femoral envelope, creating a new medull...
متن کامل