Artifact reduction from metallic dental materials in T1-weighted spin-echo imaging at 3.0 tesla.
نویسندگان
چکیده
PURPOSE To investigate and propose a method of artifact reduction arising from metallic dental materials by applying a slice-encoding for metal artifact correction (SEMAC) technique on T1-weighted spin-echo (SE) imaging at 3 Tesla. MATERIALS AND METHODS The view angle tilting (VAT) technique was adapted to conventional T1-weighted spin-echo (SE) sequence to correct the in-plane distortion, and the SEMAC technique was used for correcting the remaining through-plane distortions. Fourier transform based B0 field simulations were performed to estimate the amount of field perturbation and a scout imaging method was developed which guide in selecting the number of slice-encodings needed in SEMAC sequences. Phantoms of six different dental materials with various shapes and sizes that are used in practice (amalgam; titanium implant; gold and Ni-Cr crowns; Ni-Ti and stainless steel orthodontic wires) were imaged. In vivo images of two subjects were also acquired. The amounts of artifact reduction were quantified in phantom studies. RESULTS Compared with conventional SE imaging in phantom studies, in-plane artifacts were reduced by up to 43% in the VAT SE images and 80% in the SEMAC images. Through-plane artifacts were reduced by up to 65% in SEMAC images. In vivo SEMAC images also showed reduced artifacts. CONCLUSION The SEMAC technique can mitigate artifact caused by metallic dental materials for T1w-SE imaging.
منابع مشابه
Magnetic resonance imaging metal artifact reduction for eye plaque patient with dental braces
Purpose To determine if metal artifact reduction can minimize magnetic susceptibility artifacts in the orbits for an eye plaque brachytherapy patient with metallic dental braces. Material and methods A 62-year-old female patient with a choroidal melanoma in the right eye received a 1.5 T magnetic resonance imaging (MRI) simulation for 3D eye plaque brachytherapy planning. The protocol include...
متن کاملA Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo.
BACKGROUND AND PURPOSE A challenge with the T1-weighted postcontrast Cartesian spin-echo and turbo spin-echo brain MR imaging is the presence of flow artifacts. Our aim was to develop a rapid 2D spiral spin-echo sequence for T1-weighted MR imaging with minimal flow artifacts and to compare it with a conventional Cartesian 2D turbo spin-echo sequence. MATERIALS AND METHODS T1-weighted brain im...
متن کاملAssessment of MRI Issues at 3 Tesla for a New Metallic Tissue Marker
Purpose. To assess the MRI issues at 3 Tesla for a metallic tissue marker used to localize removal areas of tissue abnormalities. Materials and Methods. A newly designed, metallic tissue marker (Achieve Marker, CareFusion, Vernon Hills, IL) used to mark biopsy sites, particularly in breasts, was assessed for MRI issues which included standardized tests to determine magnetic field interactions (...
متن کاملImproved image contrast and scan efficiency for fat suppressed T1-weighted imaging at 3T with a spin echo two-point Dixon technique
Introduction: Fat suppressed T1-weighted imaging is often an essential component of a clinical MRI exam. Compared to several relatively newer pulse sequences (e.g., spoiled gradient echo, T1FLAIR, FSE), the conventional spin echo (SE) sequence still produces the best T1-contrast and is preferred by many radiologists for certain applications (such as for imaging of head & neck). However, inclusi...
متن کاملEffect of Low Refocusing Angle in T1-Weighted Spin Echo and Fast Spin Echo MRI on Low-Contrast Detectability: A Comparative Phantom Study at 1.5 and 3 Tesla
MRI tissue contrast is not well preserved at high field. In this work, we used a phantom with known, intrinsic contrast (3.6%) for model tissue pairs to test the effects of low angle refocusing pulses and magnetization transfer from adjacent slices on intrinsic contrast at 1.5 and 3 Tesla. Only T1-weighted spin echo sequences were tested since for such sequences the contrast loss, tissue heatin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2013