Development and implementation of an HPLC-ECD method for analysis of vitamin C in plasma using single column and automatic alternating dual column regeneration☆

نویسندگان

  • Zlatuse D. Clark
  • Elizabeth L. Frank
چکیده

OBJECTIVES Vitamin C (l-ascorbic acid) is a water-soluble micronutrient necessary for human life. Inadequate intake can lead to the fatal disease scurvy. Measurement of vitamin C is used to assess nutritional status and to monitor supplementation. The goal of this study was to develop a chromatographic method for the quantitation of vitamin C in human plasma. DESIGN AND METHODS Samples were prepared by protein precipitation, addition of internal standard, and reduction with dithiothreitol. Separation of ascorbic acid was accomplished by isocratic elution on a reverse-phase column; concentration was determined by coulometry. The method was validated through studies of assay linearity, sensitivity, imprecision, accuracy, analytical specificity, and carryover. RESULTS The new assay was developed using a single pump/single analytical column HPLC system. Results correlated well with our previously used spectrophotometric method. The analytical measurement range was 1.0-2500 µmol/L. The injection-to-injection time was 13 min. Subsequently, to increase method throughput and shorten turnaround time, a dual LC pump system with a 2-position/10-port switching valve capable of performing automatic alternating column regeneration was validated and implemented. The injection-to-injection time was reduced 2-fold to 6 min. The method was linear to 5000 µmol/L; limit of quantification was 1.9 µmol/L. Total imprecision was less than 5%. CONCLUSIONS We have developed a robust method suitable for routine clinical measurement of vitamin C in plasma specimens. The method incorporates a simplified sample preparation and a stable, non-endogenous internal standard to specifically quantify vitamin C. Faster throughput was achieved by employing an automatic alternating column regeneration system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats

A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...

متن کامل

Development and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection

A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...

متن کامل

Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA

ABSTRACT        Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...

متن کامل

Development and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection

A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016