Comparison of a point-of-care analyser for the determination of HbA1c with HPLC method
نویسندگان
چکیده
AIMS As the use of Point of Care Testing (POCT) devices for measurement of glycated haemoglobin (HbA1c) increases, it is imperative to determine how their performance compares to laboratory methods. This study compared the performance of the automated Quo-Test POCT device (EKF Diagnostics), which uses boronate fluorescence quenching technology, with a laboratory based High Performance Liquid Chromatography (HPLC) method (Biorad D10) for measurement of HbA1c. METHODS Whole blood EDTA samples from subjects (n=100) with and without diabetes were assayed using a BioRad D10 and a Quo-Test analyser. Intra-assay variation was determined by measuring six HbA1c samples in triplicate and inter-assay variation was determined by assaying four samples on 4 days. Stability was determined by assaying three samples stored at -20 °C for 14 and 28 days post collection. RESULTS Median (IQR) HbA1c was 60 (44.0-71.2) mmol/mol (7.6 (6.17-8.66) %) and 62 (45.0-69.0) mmol/mol (7.8 (6.27-8.46) %) for D10 and Quo-Test, respectively, with very good agreement (R2=0.969, P<0.0001). Mean (range) intra- and inter-assay variation was 1.2% (0.0-2.7%) and 1.6% (0.0-2.7%) for the D10 and 3.5% (0.0-6.7%) and 2.7% (0.7-5.1%) for the Quo-Test. Mean change in HbA1c after 28 days storage at -20 °C was -0.7% and +0.3% for D10 and Quo-Test respectively. Compared to the D10, Quo-Test showed 98% agreement for diagnosis of glucose intolerance (IGT and T2DM) and 100% for diagnosis of T2DM. CONCLUSION Good agreement between the D10 and Quo-Test was seen across a wide HbA1c range. The Quo-Test POCT device provided similar performance to a laboratory based HPLC method.
منابع مشابه
Evaluation of Accuracy, Precision and Agreement of Five Hba1c Measurement Methods with HPLC Reference Method
ABSTRACT Background and Objective: The current challenge of diabetes mellitus is to prevent its complications. These complications are directly associated with hyperglycemia in diabetics. The HbA1c measurement is essential for long-term glycemic control. Synchronization of HbA1c measurement is important in order to avoid discrepancies between resu...
متن کاملDetermination of Potassium Sorbate and Sodium Benzoate in "Doogh" by HPLC and Comparison with Spectrophotometry
There are various methods for the analysis of Potassium Sorbate and Sodium Benzoate in food products, but a rapid and reliable method for identification of these preservatives in Doogh (an Iranian traditional dairy drink) is a procedure, in which high performance liquid chromatography (HPLC) utilized and followed by UV diode array detection of the two preservatives. The aim of this case study w...
متن کاملDetermination of Potassium Sorbate and Sodium Benzoate in "Doogh" by HPLC and Comparison with Spectrophotometry
There are various methods for the analysis of Potassium Sorbate and Sodium Benzoate in food products, but a rapid and reliable method for identification of these preservatives in Doogh (an Iranian traditional dairy drink) is a procedure, in which high performance liquid chromatography (HPLC) utilized and followed by UV diode array detection of the two preservatives. The aim of this case study w...
متن کاملSimultaneous Determination of Carbazoles in Water Samples by Cloud Point Extraction Coupled to HPLC
Cloud point extraction (CPE) as a rapid, simple and efficient method coupled with high performance liquid chromatography (HPLC) was used for sample preparation and subsequent determination of carbazole, trinitrocarbazole (TrNC) and tetra nitro carbazole (TNC) in water samples. Some effective parameters on extraction, such as volume of Triton X-100, extraction time, extraction temperature, ionic...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کامل