Strictly-posterior thoracotomy: A minimal-access approach for construction of the modified Blalock-Taussig shunt in West African children
نویسندگان
چکیده
INTRODUCTION In resource-poor settings, the modified Blalock-Taussig shunt (MBTS) is often performed for symptomatic relief of Fallot's tetralogy. From September 2011, we adopted the strictly posterior thoracotomy (SPOT), a minimal-access technique for the MBTS and report the cosmetic advantages in this communication. METHODS We retrospectively analyzed the records of consecutive patients in whom the SPOT approach was used to construct the MBTS. Study end-points were early mortality, improvement in peripheral oxygenation, morbidity, and the cosmetic appeal. RESULTS Between September 2011 and January 2013, 15 males and 8 females, median age 4 years (1.3 - 17 years) and weight 13 kg (11 - 54 kg) underwent the MBTS through the SPOT approach. The polytetrafluoroethylene grafts used ranged from sizes 4 - 6mm (median 5mm). The median preoperative SpO2 was 74% (55% - 78%), increasing to a postoperative median value of 84% (80% - 92%). Shunts were right-sided in 22 patients and left-sided in one. There were no shunt failures. Hospital stay ranged from 7 - 10 days. There was one early death (4.3%), and two postoperative complications (re-exploration for bleeding and readmission for drainage of pleural effusion). The surgical scars had excellent cosmetic appeal: they ranged from 5-10 cm in length; all were entirely posterior and imperceptible to the patient. CONCLUSION The SPOT approach represents a safe and cosmetically superior alternative to the standard posterolateral thoracotomy, the scar being imperceptible to the patient. The excellent cosmetic appeal and preservation of body image makes this approach particularly attractive in children and young adults.
منابع مشابه
Pseudoaneurysm following modified Blalock Taussig shunt.
The modified Blalock-Taussig (BT) shunt is a common palliative procedure for congenital cyanotic heart disease (CHD) with diminished pulmonary blood flow(1). In developing countries, definitive surgery usually gets delayed due to limited resources and expertise(2). Children with cyanotic CHD and BT shunt often present to the pediatrician resulting in some of the complications of BT shunt being ...
متن کاملComplications of modified Blalock-Taussig shunts mimicking pulmonary disease.
The modified Blalock-Taussig shunt is commonly performed as early palliation in cyanotic congenital heart disease. To highlight unusual diagnostic problems in such patients, two cases are reported in whom shunt complications were initially diagnosed as lobar pneumonia and tuberculosis, respectively. The children, an 8 month old boy and a 3 year old boy, had false aneurysm secondary to infection...
متن کاملClosure of Blalock-Taussig shunts using a new detachable coil device.
Two children underwent interventional closure of a modified Blalock-Taussig shunt using a new detachable coil system (Duct-Occlud). This procedure has advantages over currently available materials to occlude these and other communications between the systemic and pulmonary circulations.
متن کاملFalse aneurysm following modified Blalock-Taussig shunt.
A nine month old infant with life threatening tracheal compression due to a Blalock-Taussig shunt aneurysm is described. Successful surgical management is discussed.
متن کاملModified Blalock-Taussig shunt versus ductal stenting for palliation of cardiac lesions with inadequate pulmonary blood flow.
OBJECTIVE The modified Blalock-Taussig shunt is the most commonly used palliative procedure for infants with ductal-dependent pulmonary circulation. Recently, catheter-based stenting of the ductus arteriosus has been used by some centers to avoid surgical shunt placement. We evaluated the durability and safety of ductal stenting as an alternative to the modified Blalock-Taussig shunt. METHODS...