Performance and Availability Analyses of PV Generation Systems in Taiwan

نویسندگان

  • H. S. Huang
  • J. C. Jao
چکیده

The purpose of this article applies the monthly final energy yield and failure data of 202 PV systems installed in Taiwan to analyze the PV operational performance and system availability. This data is collected by Industrial Technology Research Institute through manual records. Bad data detection and failure data estimation approaches are proposed to guarantee the quality of the received information. The performance ratio value and system availability are then calculated and compared with those of other countries. It is indicated that the average performance ratio of Taiwan’s PV systems is 0.74 and the availability is 95.7%. These results are similar with those of Germany, Switzerland, Italy and Japan. Keywords—availability, performance ratio, PV system, Taiwan

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Non-linear Control of the Four-Leg Inverter with Decoupled Model and Fast Dynamic Response for PV Generation Systems

Distributed generation (DG) will play an important role in future power generation systems, especially in stand-alone applications. Three phase four-leg inverter is a well-known topology which can be used as an interface power converter for DGs. Thanks to the fourth leg to provide the neutral path, the four-leg inverter is able to supply balanced loads as well as unbalanced loads. In this paper...

متن کامل

Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT

The single-phase transformerless grid-connected photovoltaic (PV) systems, mainly the low-power single-phase systems, require high efficiency, small size, lightweight, and low-cost grid-connected inverters. However, problems such as leakage current, the DC current injection and safety issues are incorporated with transformerless grid-connected PV inverters. Besides, the new standards such as Lo...

متن کامل

Performance Modeling of Power Generation System of a Thermal Plant

The present paper discusses the development of a performance model of power generation system of a thermal plant for performance evaluation using Markov technique and probabilistic approach. The study covers two areas: development of a predictive model and evaluation of performance with the help of developed model. The present system of thermal plant under study consists of four subsystems with...

متن کامل

General Overview of Maximum Power Point Tracking Methods for Photovoltaic Power Generation Systems

Maximum power point tracking controller is essential to obtain the maximum power from a solar array in the photovoltaic systems as the PV power module varies with the temperature and solar irradiation. In this paper, several methods for the MPPT of the PV systems are discussed and it can to be used as a Helpful reference for the upcoming MPPT user in the PV applications.

متن کامل

Trastuzumab increases pulmonary vein arrhythmogenesis through modulating pulmonary vein electrical and conduction properties via phosphatidylinositol 3-kinase signaling

Objective(s): Drug-induced atrial fibrillation (AF) is considered an adverse effect of chemotherapeutic drugs. AF is a crucial risk factor for stroke, heart failure, myocardial infarction, and mortality. Pulmonary veins (PVs) are considered triggers inducing AF, and the sinoatrial node (SAN) may modulate PV activity and participate in AF genesis. AF was associated with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013