Slant or occlusion: global factors resolve stereoscopic ambiguity in sets of horizontal lines

نویسندگان

  • Barbara Gillam
  • Philip M. Grove
چکیده

Perceived slant was measured for horizontal lines aligned on one side and of varying lengths whose length disparity was either a constant linear amount for all lines (consistent with uniocular occlusion) or proportional to line length (consistent with global slant). Although the disparity of any line was ambiguous with respect to these two possibilities, slant of individual lines did not occur in the former case, but a subjective contour in depth was reported along the alignment. For proportional disparity of the set, global slant was seen. Adding a constant length to each line on the invalid eye for occlusion resulted in multiple slants. Smooth uniocular variations in alignment shape elicited subjective contours slanting or curving in depth. Global context can disambiguate the depth status of individual disparate lines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early dynamics of stereoscopic surface slant perception

Surface orientation is an important visual primitive that can be estimated from monocular or binocular (stereoscopic) signals. Changes in motor planning occur within about 200 ms after either type of signal is perturbed, but the time it takes for apparent (perceived) slant to develop from stereoscopic cues is not known. Apparent slant sometimes develops very slowly (Gillam, Chambers, & Russo, 1...

متن کامل

Horizontal and vertical disparity, eye position, and stereoscopic slant perception

The slant of a stereoscopically defined surface cannot be determined solely from horizontal disparities or from derived quantities such as horizontal size ratio (HSR). There are four other signals that, in combination with horizontal disparity, could in principle allow an unambiguous estimate of slant: the vergence and version of the eyes, the vertical size ratio (VSR), and the horizontal gradi...

متن کامل

Monocular and binocular edges enhance the perception of stereoscopic slant

Gradients of absolute binocular disparity across a slanted surface are often considered the basis for stereoscopic slant perception. However, perceived stereo slant around a vertical axis is usually slow and significantly under-estimated for isolated surfaces. Perceived slant is enhanced when surrounding surfaces provide a relative disparity gradient or depth step at the edges of the slanted su...

متن کامل

Anisotropies in the perception of stereoscopic surfaces: the role of orientation disparity.

We measured stereoscopic slant detection thresholds for surfaces slanting about a horizontal or a vertical axis. For random-dot covered surfaces, 1.25 deg of slant was required to detect slant about a horizontal axis, whereas 2.1 deg of slant was required to detect slant about a vertical axis. This anisotropy could be due to the fact that orientation disparities, which contain information about...

متن کامل

The influence of large scanning eye movements on stereoscopic slant estimation of large surfaces

The results of several experiments demonstrate that the estimated magnitude of perceived slant of large stereoscopic surfaces increases with the duration of the presentation. In these experiments, subjects were free to make eye movements. A possible explanation for the increase is that the visual system needs to scan the stimulus with eye movements (which take time) before it can make a reliabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2004