Time-resolved characteristics of deuteron-beam generated by plasma focus discharge

نویسندگان

  • Lian-Kuang Lim
  • Seong-Ling Yap
  • D A Bradley
چکیده

The plasma focus device discussed herein is a Z-pinch pulsed-plasma arrangement. In this, the plasma is heated and compressed into a cylindrical column, producing a typical density of > 1025 particles/m3 and a temperature of (1-3) × 107 oC. The plasma focus has been widely investigated as a radiation source, including as ion-beams, electron-beams and as a source of x-ray and neutron production, providing considerable scope for use in a variety of technological situations. Thus said, the nature of the radiation emission depends on the dynamics of the plasma pinch. In this study of the characteristics of deuteron-beam emission, in terms of energy, fluence and angular distribution were analyzed. The 2.7 kJ plasma focus discharge has been made to operate at a pressure of less than 1 mbar rather than at its more conventional operating pressure of a few mbar. Faraday cup were used to determine deuteron-beam energy and deuteron-beam fluence per shot while CR-39 solid-state nuclear track detectors were employed in studying the angular distribution of deuteron emission. Beam energy and deuteron-beam fluence per shot have been found to be pressure dependent. The largest value of average deuteron energy measured for present conditions was found to be (52 ± 7) keV, while the deuteron-beam fluence per shot was of the order of 1015 ions/m2 when operated at a pressure of 0.2 mbar. The deuteron-beam emission is in the forward direction and is observed to be highly anisotropic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه‌گیری قطبش باریکه دوترون قبل و بعد از شتاب گرفتن

Beam polarization measurement in scattering experiments with a high accuracy and the lowest possible cost is an important issue. In this regard, deuteron beam polarization was measured in the low-energy beam line easily with a relatively low cost procedure and in a very short time by Lamb Shift Polarimeter (LSP). Also, the beam polarization has been measured in high-energy beam line with BINA. ...

متن کامل

Double Langmuir probe measurement of plasma parameters in a dc glow discharge

In this paper, plasma main characteristics such as electron mean temperature, electron number density, and oscillation frequency have been measured experimentally using the double Langmuir probe diagnostic system. In our experiment, the plasma was generated by applying the low pressure dc glow discharge in several common gases. The experimental results indicated the highest plasma density and o...

متن کامل

Application of a mode-locked fiber laser for highly time resolved broadband absorption spectroscopy and laser-assisted breakdown on micro-plasmas

Absorption spectroscopy is known to be a powerful tool to gain spatially and temporally resolved information on excited and reactive species in a plasma discharge. Furthermore, the interaction of the discharge with short intense laser pulses can trigger the ignition and the transition into other transient states of the plasma. In this context laser-assisted ‘pump-probe’ experiments involving si...

متن کامل

Size Distribution Measurement of Candle\'s Soot Nanoparticles by Using Time Resolved Laser Induced Incandescence

Time resolved laser induced incandescence (LII) technique is used to measure size distribution of soot nanoparticles of candle's flame. Pulsed Nd:YAG laser is used to heat nanoparticles to incandescence temperature and the resulting signal is measured. Mass and energy balance equations are numerically solved to calculate temperature of soot particles in low fluence regime. Assuming Plank black ...

متن کامل

Influence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe

Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018