Noise variance of an RF receive array reflects respiratory motion: a novel respiratory motion predictor
نویسندگان
چکیده
Purpose: MRI is a relatively slow imaging modality. Patient respiratory motion significantly reduces diagnostic image quality, especially in the abdomen. Usually, motion is detected with a respiratory belt and/or navigators[1]. The belt is an extra device which demands careful positioning on the patient to be a reliable indicator of the respiratory motion. The navigator[2] is an MR based sensor and, thus, contact free. However, it requires additional planning and can interfere with the steady state magnetization, leading to image artifacts. As an alternative to the latter methods, it has been shown that patient motion can be monitored with the RF coil impedance measurements[3,4]. Since an RF coil is a part of every MRI system, there is no need for a separate sensor (i.e. pneumatic belt) or extra MR acquisition (i.e. navigator). Nevertheless, the method requires additional hardware: directional couplers[3] or pick-up coils[4]. We propose to detect the motion induced impedance variation by means of noise measurements. It is well-known that thermal noise variance () in an RF coil is directly proportional to the coil's resistance (real part of impedance) and, thus, can potentially be an alternative to the direct RF coil impedance measurement. Here, using clinical MR systems we investigated the feasibility of monitoring the respiratory motion with the RF coil's . Moreover, noise covariance matrix of a receive array contains spatial information which can potentially be used for motion prediction. Methods: The experiments were performed on clinical 1.5/3 T MR scanners with 16 channel body receive arrays. RF and gradients were switched off during a standard GRE MR sequence. Signal was collected with a dwell time of 1.35/1 μs (max BW), TR=3.1/2.5 ms, number of collected points per TR: 1000. At the same time, signal from the respiratory belt was recorded. Subjects were asked to perform free breathing (~1 min), deep breathing (~1 min) and breath holds in exhale and inhale positions for ~16 seconds. In addition, at 3T, the subject was asked to perform four breathing scenarios: free, deep, deep with holds and fast. was calculated for each TR. The obtained temporal modulation of was evaluated and compared to the respiratory belt signal. A moving average filter (length 1.2 s) was applied to the temporal modulation of . Power spectra were calculated of both and respiratory belt signals to compare their dominant frequencies. For each coil of the 16 channel receive arrays, a relative amplitude of their modulation (i.e. sensitivity to the respiratory motion) was calculated. Results: The signal picked up by the RF coil consisted only of thermal noise (Fig 1A). Calculated and filtered variance of this signal revealed an apparent periodic modulation of the (Fig 1B) similar to the respiratory belt signal (Fig 1C). For the deep breathing the modulation was slower and had larger amplitude (Fig 1D) analogous to the respiratory belt signal (Fig 1E). The spectral analysis (Fig 1F) showed that the dominant frequencies of both and respiratory belt signals were the same. The base line drift of the signal (Fig 1B) appeared at very low frequency (~0.05Hz) in the power spectrum. Higher harmonics were present in the modulation. Noise measurements at 3T also showed periodic, respiratory motion induced change of the . The sensitivity of the RF coil to the motion depends on its' location with respect to the body (Fig 2A). Four out of 16 coils' temporal modulations are shown in Fig 2B. Their location (close to the diaphragm) is illustrated in Fig 2A. During the breath holds the thermal noise variance had no periodic modulation and only negligible fluctuations occurred. Similar results (not shown) were observed for 1.5T. Note, that a movement (or start of breathing) of the subject at the end of the second breath hold led to a clearly visible increase of the in all four coils (Fig 2, arrows). Dominant frequencies of the respiratory belt signals were also dominant (except for the first breathing condition) in the power spectra (Fig 3). Similar to 1.5T, RF coil had higher frequency harmonics which did not appear in the respiratory belt power spectra. Discussion: Thermal noise variance of RF coil is sensitive to the subject motion because of the motion induced changes of RF coil resistance. Noise sampling was performed within a standard MR sequence by switching off the RF and gradient parts of the sequence. In order to combine noise measurements with an actual MR experiment, noise sampling can be easily performed during "dead time" of TR. To exclude/minimize signal from the residual transverse magnetization, the demodulation frequency can be shifted by 1 or 2 MHz during the noise measurements. Alternatively, one channel of receiver array can be tuned to a different resonance frequency and used to monitor continuously the respiratory motion with
منابع مشابه
Reducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملThe influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study
Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملAutomatic detection of liver tumor motion by fluoroscopy images
Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...
متن کاملAn Alternative Concept for Non-Sequence Interfering, Contact-free Respiration Monitoring
Introduction Respiratory motion is a challenging problem in MRI, especially in abdominal and cardiac imaging. Appropriate motion detection and correction is needed to cope with this problem, and to improve diagnostic image quality. The respiratory navigator [1] is an existing MR based motion detection method and thus contact-free, it provides very good accuracy but has several disadvantages: th...
متن کامل