Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy

نویسندگان

  • Giselle Naback Lemes Vilani
  • Antônio Carlos de Oliveira Ruellas
  • Carlos Nelson Elias
  • Cláudia Trindade Mattos
چکیده

OBJECTIVE To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability. METHODS Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three (3) MI with acid etched surfaces (rough) were inserted. The two distal MI in each hemiarch received an immediate load of 1.0 N for 16 weeks, whereas the MI in the mesial extremity was not subject to loading. Stability was measured by insertion and removal torque, initial and final mobility and by inter mini-implant distance. RESULTS There was no statistical behavioral difference between smooth and rough MI. High insertion torque and reduced initial mobility were observed in all groups, as well as a reduction in removal torques in comparison with insertion torque. Rough MI presented higher removal torque and lower final mobility in comparison to smooth MI. MI did not remain static, with displacement of rough MI being smaller in comparison with smooth MI, but with no statistical difference. CONCLUSIONS MI primary stability was greater than stability measured at removal. There was no difference in stability between smooth and rough MI when assessing mobility, displacement and insertion as well as removal torques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Stability of Surface-Treated Mini-Implants in Diabetic Rabbits

Introduction. The purpose of this study was to investigate effects of surface treatment of mini-implants in diabetes-induced rabbits by comparing osseointegration around mini-implants. Methods. Twelve New Zealand white rabbits were divided into two groups (alloxan-induced diabetic group and control group). A total of 48 mini-implants were placed after four weeks of diabetic induction. 24 mini-i...

متن کامل

Load-related implant reaction of mini-implants used for orthodontic anchorage.

The purpose of this study was to determine the clinical and biomechanical outcome of two different titanium mini-implant systems activated with different load regimens. A total of 200 mini-implants (102 Abso Anchor and 98 Dual Top) were placed in the mandible of eight Göttinger minipigs. Two implants each were immediately loaded in opposite direction by various forces (100, 300 or 500 cN) throu...

متن کامل

Effects of structured written feedback by cards on medical students’ performance at mini clinical evaluation exercise (Mini-CEX) in an outpatient clinic

Introduction: Feedback cards are recommended as a feasible toolfor structured written feedback delivery in clinical education whileeffectiveness of this tool on the medical students’ performanceis still questionable. The purpose of this study was to comparethe effects of structured written feedback by cards as well asverbal feedback versus verbal feedback alone on the clinicalperformance of med...

متن کامل

Full mouth rehabilitation with fixed prostheses in the case of unaligned and malpositioned implants: clinical report

Full mouth rehabilitation with fixed implant supported prostheses is one of the challenging treatments, because important factors in aesthetic and function should be considered. Implants' alignments and locations should be planned before the insertion unless the improper inclination and location of implants would lead to difficulties in patient's comfort, oral hygiene problem and inability to r...

متن کامل

Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study

Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2015