Transverse Tripolar Stimulation for Selective Fns

نویسنده

  • Jan Holsheimer
چکیده

.4bstruct Various anode-cathode configurations in a nerve cujf were modeled in ordcr to optimize its spatial selectivity characterktics for FNS. Apart from usual configurations (nronopole, bipole, longitudinal tripole, “steering” anode), a transverse t r ipoh configuration (cenfral cathode) was examined The model predicrions were verified bey mute animal experiments. It is concluded that a transverse tripole activates superficial nerve fibers in a more selective way than other configurations do.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of transverse tripolar spinal cord stimulator for the relief of chronic low back pain from failed back surgery.

BACKGROUND Failed back surgery syndrome is a common clinical entity for which spinal cord stimulation has been found to be an effective mode of analgesia, but with variable success rates. OBJECTIVE To determine if focal stimulation of the dorsal columns with a transverse tripolar lead might achieve deeper penetration of the electrical stimulus into the spinal cord and therefore provide greate...

متن کامل

A comparative study on soleus H reflex parameters using vertebral column and peripheral nerve stimulation

Although low-threshold transcutaneous electrical nerve stimulation (TENS) is a modality used for control of pain, but its effect in the control of spasticity and change of excitability of a motor neuron is controversial. Therefore, this study was conducted to evaluate the effects of 15-min tripolar TENS of vertebral column and bipolar TENS of common peroneal nerve (300 µs width, 50 Hz) on synap...

متن کامل

Metabolic responses to arm ergometry and functional neuromuscular stimulation.

The hips and lower extremities of four complete paraplegic male subjects (T-6, T-7, T-8, and T-11) were stimulated with functional neuromuscular stimulation (FNS) via transcutaneous intramuscular electrodes (20 mA, 0-150 pulse width, and 20 Hz). Cardiopulmonary (CP) and/or cardiovascular (CV) responses were measured during maximal (seated) arm ergometry (AE), FNS, and FNS + AE. Subjects' lower ...

متن کامل

The effects of vertebral column tripolar electrical stimulation with various intensities on soleus and gastrocnemius H-reflex and Mh wave recruitment curve

Abstract: To assess the effect of penetration depth of the surface tripolar electrical stimulation, Tripolar TENS was applied with different intensities (equal to sensory threshold (ST), 1.25 ST, 1.5 ST) on vertebral column of twenty healthy and three hemiplegic subjects. The cathode of TENS was laid on the T11 vertebra and anodes were put 3cm apart from cathode, longitudinally and in the anod...

متن کامل

Intensity coding in electric hearing: effects of electrode configurations and stimulation waveforms.

OBJECTIVES Current cochlear implants typically stimulate the auditory nerve with biphasic pulses and monopolar electrode configurations. Tripolar stimulation can increase spatial selectivity and potentially improve place pitch related perception but requires higher current levels to elicit the same loudness as monopolar stimulation. The present study combined delayed pseudomonophonasic pulses, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004