Development of backgammon-type multiwire proportional counters for the detection of x rays

نویسندگان

  • J. A. Kimpton
  • M. N. Kinnane
  • C. T. Chantler
چکیده

A multiwire proportional counter !MWPC" based on a backgammon-type design has been developed for the detection of x-ray photons in two dimensions over the energy range of 4–6 keV. The MWPC was designed for operation in an experimental spectroscopy application requiring single photon counting over a wide range of count rates, high photon detection efficiency and resolution, and a highly linear response function across the detector face. A model based on attenuation of the incident x-ray beam by the various components of the detector is presented and highlights key areas for efficiency optimization. The design, construction, testing procedure, and performance of the backgammon MWPC are presented and all objectives are met including a particularly impressive differential nonlinearity. © 2006 American Institute of Physics. #DOI: 10.1063/1.2237760$

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The correction of systematic image deformations inherent to two-dimensional proportional counters

Two-dimensional backgammon configuration and multiwire gas proportional counters have been in use for decades in the field of x-ray physics for high-precision or high-flux experiments. Systematics inherent to this type of detector lead to image distortions that are often overlooked or extremely difficult to quantify. They are usually seen as intrinsic to the detector performance, leading to los...

متن کامل

The Energy Resolution of Xenon-Neon filled Gas Proportional-Scintillation Counters for X-Rays Below 2 keV

The energy spectra of x-rays with energies below 2 keV measured at atmospheric pressure with standard Xe gas detectors, such as gas proportional-scintillation counters (GPSC), exhibit distortions that are related to losses of electrons and fluorescence photons to the radiation window. In this work, a Monte Carlo simulation method that takes into account these losses investigates the use of Xe-N...

متن کامل

Xenon–Neon Gas Proportional-Scintillation Counters for X-Rays Below 2 keV: A Monte Carlo Simulation Study

The energy spectra of X-rays with energies below 2 keV measured at atmospheric pressure with standard Xe gas detectors, such as gas proportional-scintillation counters, exhibit distortions that are related to losses of electrons and fluorescence photons to the radiation window. In this paper, a Monte Carlo simulation method that takes into account these losses investigates the use of Xe–Ne mixt...

متن کامل

The primary energy spectrum of cosmic rays obtained by muon density measurements at KASCADE

Spectra of local muon densities in high-energy extensive air-showers (EAS) are presented as signature of the primary cosmic ray energy spectrum in the knee region. The KASCADE central detector, with its two layers of multiwire proportional chambers and with a layer of scintillation counters, enables the measurements of muon densities at two different threshold energies. The spectra have been re...

متن کامل

THE COSMIC - RAY 3 He / 4 He RATIO FROM 200 MeV PER NUCLEON ~ 1 TO 3 . 7 GeV PER NUCLEON

The abundances of cosmic-ray helium isotopes between 0.2 and 3.7 GeV nucleon~1 were measured by the Isotope Matter Antimatter Experiment (IMAX) during a Ñight from Lynn Lake, Manitoba, Canada on 1992 July 16È17. The IMAX balloon-borne magnetic spectrometer realized a direct measurement of the charge, the velocity, and the rigidity of cosmic rays using plastic scintillators, a high-resolution ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009