Optical response to LASIK surgery for myopia from total and corneal aberration measurements.

نویسندگان

  • S Marcos
  • S Barbero
  • L Llorente
  • J Merayo-Lloves
چکیده

PURPOSE To evaluate the optical aberrations induced by LASIK refractive surgery for myopia on the anterior surface of the cornea and the entire optical system of the eye. METHODS Total and corneal aberrations were measured in a group of 14 eyes (preoperative myopia ranging from -2.5 to -13 D) before and after LASIK surgery. Total aberrations were measured using a laser ray-tracing technique. Corneal aberrations were obtained from corneal elevation maps measured using a corneal system and custom software. Corneal and total wave aberrations were described as Zernike polynomial expansions. Root-mean-square (RMS) wavefront error was used as a global optical quality metric. RESULTS Total and corneal aberrations (third-order and higher) showed a statistically significant increase after LASIK myopia surgery, by a factor of 1.92 (total) and 3.72 (corneal), on average. This increase was more pronounced in patients with the highest preoperative myopia. There is a good correlation (r = 0.97, P < 0.0001) between the aberrations induced in the entire optical system and those induced in the anterior corneal surface. However, the anterior corneal spherical aberration increased more than the total spherical aberration, suggesting also a change in the spherical aberration of the posterior corneal surface. Pupil centration and internal optical aberrations, which are not accounted for in corneal topography, play an important role in evaluating individual surgical outcomes. CONCLUSIONS Because LASIK surgery induces changes in the anterior corneal surface, most changes in the total aberration pattern can be attributed to changes in the anterior corneal aberrations. However, because of individual interactions of the aberrations in the ocular components, a combination of corneal and total aberration measurements is critical to understanding individual outcomes, and by extension, to designing custom ablation algorithms. This comparison also reveals changes in the internal aberrations, consistent with the posterior corneal changes reported using scanning slit corneal topography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia.

PURPOSE To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality. METHODS Total and corneal aberrations were measured before and after standard hyperopic LASIK in 13 eyes (preoperative spherical equivalent refractive error +3.17 +/- 1.10 D). The Chiron Technolas 217C laser with PlanoScan was used. Total aberrations (measur...

متن کامل

Aberrations and visual performance following standard laser vision correction.

PURPOSE To relate the change of ocular aberrations with the change of visual performance produced by standard laser in situ keratomileusis (LASIK) for myopia. METHODS Aberrations and visual performance were measured before and after surgery in 22 eyes. Total aberrations were measured using a laser ray tracing technique. Corneal aberrations were obtained using a commercial videokeratoscope and...

متن کامل

Comparison of real and computer-simulated outcomes of LASIK refractive surgery.

Computer simulations of alternative LASIK ablation patterns were performed for corneal elevation maps of 13 real myopic corneas (range of myopia, -2.0 to -11.5 D). The computationally simulated ablation patterns were designed with biconic surfaces (standard Munnerlyn pattern, parabolic pattern, and biconic pattern) or with aberrometry measurements (customized pattern). Simulated results were co...

متن کامل

Comparison of corneal and total ocular aberrations before and after myopic LASIK.

PURPOSE To assess the compensation of total ocular and corneal wavefront aberrations after conventional myopic LASIK. METHODS This study comprised 57 eyes of 57 patients. Total and corneal aberrations were measured preoperatively and 3 months postoperatively using the OPD-Scan (NIDEK Co Ltd) aberrometer. Total and corneal aberrations root-mean-square (RMS) was calculated out to the 6th Zernik...

متن کامل

The Changes of Posterior Corneal Surface and High-Order Aberrations after Refractive Surgery in Moderate Myopia

PURPOSE To compare forward shift of posterior corneal surface and higher-order aberration (HOA) changes after LASIK, LASEK, and wavefront-guided LASEK surgery in moderate myopia METHODS One hundred eighty four eyes undergoing LASIK, LASEK and wavefront-guided LASEK with VISX STAR S4 were included in this study. The posterior corneal elevation was measured with Orbscan before, 2 and 4 months a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 42 13  شماره 

صفحات  -

تاریخ انتشار 2001