Optimization of encoding gradients for MR-ARFI.
نویسندگان
چکیده
MR acoustic radiation force imaging provides a promising method to monitor therapeutic ultrasound treatments. By measuring the displacement induced by the acoustic radiation force, MR acoustic radiation force imaging can locate the focal spot, without a significant temperature rise. In this work, the encoding gradient for MR acoustic radiation force imaging is optimized to achieve an enhanced accuracy and precision of the displacement measurement. By analyzing the sources of artifacts, bulk motion and eddy currents are shown to introduce errors to the measurement, and heavy diffusion-weighting is shown to result in noisy displacement maps. To eliminate these problems, a new encoding scheme is proposed, which utilizes a pair of bipolar gradients. Improved precision is achieved with robustness against bulk motion and background phase distortion, and improved accuracy is achieved with reduced diffusion-weighting and optimized encoding pulse width. The experiment result shows that the signal-to-noise ratio can be enhanced by more than 2-fold. These significant improvements are obtained at no cost of scan time or encoding sensitivity, enabling the detection of a displacement less than 0.l microm in a gel phantom with MR acoustic radiation force imaging.
منابع مشابه
Rapid FUS Focal Spot Localization based on MR-ARFI
Introduction For various therapeutic applications, focused ultrasound (FUS) is used in either thermal mode or in mechanical mode. Mechanical mode FUS has been used for temporary blood brain barrier disruption and for targeted drug delivery. Monitoring of such treatments remains a technical challenge since there should be no significant temperature increase in the focal spot, unlike in case of t...
متن کاملSNR Trade-offs in MR-ARFI of Focused Ultrasound in the Brain
Introduction MR guided focused ultrasound (MRgFUS) is of interest in the treatment of various brain pathologies, such as tumors [1] and neuropathic pain [2]. Localization of the ultrasound focal spot is currently achieved with a low temperature rise sonication. An alternative would be to use MR acoustic radiation force imaging (MRARFI) [3,4,5] without a temperature rise at all. In one implement...
متن کاملFocal Spot Visualization in MRgFUS of the Breast: MR-ARFI vs. T1-weighted FSE
Introduction MRI guided focused ultrasound (MRgFUS) as a non-invasive breast cancer treatment has recently shown promising results in clinical trials [1,2,3]. Currently, during the planning stage of MRgFUS in the breast, a low temperature test spot is created to verify the actual location of the focal spot in relation to the planned position [1,2]. The test spots are visualized using proton res...
متن کاملEvaluation of bipolar encoding configurations for spin echo MR-ARFI
Introduction MR-based Acoustic Radiation Force (MR-ARFI) has been recently proposed as a tool for the targeting, monitoring and assessment of focused ultrasound (FUS) therapy [16]. Several bipolar encoding schemes have been introduced for spin echo based MR-ARFI [3-5](Fig. 1). The purpose of this work was to evaluate the performance of three encoding schemes by modeling and experimentally testi...
متن کاملRapid MR-ARFI method for focal spot localization during focused ultrasound therapy.
MR-guided focused ultrasound (FUS) is a noninvasive therapy for treating various pathologies. MR-based acoustic radiation force imaging (MR-ARFI) measures tissue displacement in the focal spot due to acoustic radiation force. MR-ARFI also provides feedback for adaptive focusing algorithms that could correct for phase aberrations caused by the skull during brain treatments. This work developed a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 63 4 شماره
صفحات -
تاریخ انتشار 2010