Scatter correction in digital mammography based on image deconvolution.

نویسندگان

  • J L Ducote
  • S Molloi
چکیده

X-ray scatter is a major cause of nonlinearity in densitometry measurements using digital mammography. Previous scatter correction techniques have primarily used a single scatter point spread function to estimate x-ray scatter. In this study, a new algorithm to correct x-ray scatter based on image convolution was implemented using a spatially variant scatter point spread function which is energy and thickness dependent. The scatter kernel was characterized in terms of its scattering fraction (SF) and scatter radial extent (k) on uniform Lucite phantoms with thickness of 0.8-8.0 cm. The algorithm operates on a pixel-by-pixel basis by grouping pixels of similar thicknesses into a series of mask images that are individually deconvolved using Fourier image analysis with a distinct kernel for each image. The algorithm was evaluated with three Lucite step phantoms and one anthropomorphic breast phantom using a full-field digital mammography system at energies of 24, 28, 31 and 49 kVp. The true primary signal was measured with a multi-hole collimator. The effect on image quality was also evaluated. For all 16 studies, the average mean percentage error in estimating the true primary signal was found to be -2.13% and the average rms percentage error was 2.60%. The image quality was seen to improve at every energy up to 25% at 49 kVp. The results indicate that a technique based on a spatially variant scatter point spread function can accurately estimate x-ray scatter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new approach to scatter correction in SPECT images based on Klein_Nishina equation

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

The Effect of FEW Scatter Correction Method in In-111 Imaging

Introduction: In nuclear medicine imaging, detection of the scattered photons along with the primary photons is one of the major problems that can lead to a decrease in ddiagnostic accuracy. Therefore, use of a suitable scatter correction method can help to improve of the image quality and increase of diagnostic accuracy. The aim of this study is evaluation of five energy wind...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

Estimation of scattered radiation in digital breast

13 Digital breast tomosynthesis (DBT) is a promising technique to overcome the tissue 14 superposition limitations found in planar 2D X-ray mammography. However, as most 15 DBT systems do not employ an anti-scatter grid, the levels of scattered radiation 16 recorded within the image receptor are significantly higher than that observed in planar 17 2D X-ray mammography. Knowledge of this field i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 55 5  شماره 

صفحات  -

تاریخ انتشار 2010