Accuracy of float testing for metered-dose inhaler canisters.

نویسندگان

  • Tina Penick Brock
  • Andrea M Wessell
  • Dennis M Williams
  • James F Donohue
چکیده

OBJECTIVE To characterize and evaluate canister floating patterns of three commercially available metered-dose inhalers (MDIs) with varying amounts of medication remaining. DESIGN Four canisters each of three asthma medications were studied. MDIs were actuated every 30 seconds to 60 seconds, and canisters were weighed and floated at 100%, 75%, 66%, 50%, 33%, 25%, 10%, and 0% of remaining labeled actuations. Position of the canisters and percentage submersion in water were recorded. SETTING Controlled laboratory. RESULTS We observed differences among the products with regard to canister floating behavior at varying levels of fullness. All canisters were completely submerged with the nozzle up at two-thirds full and greater. The canisters remained nozzle-up and were submerged to varying levels at the half-full point. When observed at less than half full, canisters inverted and floated nozzle down. Positions of the canisters varied among products at less than half full. No canister was fully tilted when all labeled actuations were used. CONCLUSION Float characteristics are product-specific and a function of canister size, design, content, and method of testing. Clinicians and asthma educators should not advise patients to use a float test to assess the amount of medication remaining in an MDI. Recommendations from the National Asthma Education and Prevention Program of the National Heart, Lung, and Blood Institute suggest that the only reliable method for determining the number of doses remaining in a canister is to subtract the number of doses used from the number available.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metered dose inhalers and spacer devices.

Easy to carry, highly effective and extremely safe, allowing accurate, consistent dose delivery, metered dose inhalers are the inhalation devices doctors and patients choose most readily the world over. Clinical response, however, may be affected by the inhalation technique used and the precise formulation in the canisters. The purpose of this review is to consider metered dose inhalers, add on...

متن کامل

How do patients determine that their metered-dose inhaler is empty?

STUDY OBJECTIVE To evaluate how patients determined that pressurized metered-dose inhaler (pMDI) canisters were empty and to measure pMDI depletion under different circumstances in the laboratory. SETTING Most of the study was performed in a university research laboratory. PARTICIPANTS Fifty consecutive patients attending the Brenner Children's Hospital Asthma Center were initially question...

متن کامل

Achieving good adherence to inhaled corticosteroids after weighing canisters of asthmatic children

Background: The metered-dose inhalers (MDIs) currently available for inhaled corticosteroid delivery do not offer an integrated dose counter; therefore, it is difficult to evaluate adherence of patients. The present authors developed a linear regression equation using canister weight to calculate the number of doses actuated from the MDIs. This study aimed to assess medical adherence after the ...

متن کامل

Lung deposition of budesonide from a pressurized metered-dose inhaler attached to a spacer.

The absolute systemic availability and pulmonary deposition of budesonide inhaled from a pressurized metered-dose inhaler (pMDI) attached to a Nebuhaler spacer was determined in 15 healthy subjects. The study was of an open cross-over design. Each subject randomly received three single doses of budesonide on separate days: 0.5 mg given intravenously and 1.0 mg (0.2 mg x 5) by inhalation from a ...

متن کامل

Validation of a metered dose inhaler electronic monitoring device: implications for asthma clinical trial use.

BACKGROUND The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Pharmaceutical Association

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 2002