Intracranial time-resolved contrast-enhanced MR angiography at 3T.

نویسندگان

  • T A Cashen
  • J C Carr
  • W Shin
  • M T Walker
  • S F Futterer
  • A Shaibani
  • R M McCarthy
  • T J Carroll
چکیده

BACKGROUND AND PURPOSE A method is presented for high-temporal-resolution MR angiography (MRA) using a combination of undersampling strategies and a high-field (3T) scanner. Currently, the evaluation of cerebrovascular disorders involving arteriovenous shunting or retrograde flow is accomplished with conventional radiographic digital subtraction angiography, because of its high spatial and temporal resolutions. Multiphase MRA could potentially provide the same diagnostic information noninvasively, though this is technically challenging because of the inherent trade-off between signal intensity-to-noise ratio (S/N), spatial resolution, and temporal resolution in MR imaging. METHODS Numerical simulations addressed the choice of imaging parameters at 3T to maximize S/N and the data acquisition rate while staying within specific absorption rate limits. The increase in S/N at 3T was verified in vivo. An imaging protocol was developed with S/N, spatial resolution, and temporal resolution suitable for intracranial angiography. Partial Fourier imaging, parallel imaging, and the time-resolved echo-shared acquisition technique (TREAT) were all used to achieve sufficient undersampling. RESULTS In 40 volunteers and 10 patients exhibiting arteriovenous malformations or fistulas, intracranial time-resolved contrast-enhanced MRA with high acceleration at high field produced diagnostic-quality images suitable for assessment of pathologies involving arteriovenous shunting or retrograde flow. The technique provided spatial resolution of 1.1 x 1.1 x 2.5 mm and temporal resolution of 2.5 seconds/frame. The combination of several acceleration methods, each with modest acceleration, can provide a high overall acceleration without the artifacts of any one technique becoming too pronounced. CONCLUSION By taking advantage of the increased S/N provided by 3T magnets over conventional 1.5T magnets and converting this additional S/N into higher temporal resolution through acceleration strategies, intracranial time-resolved MRA becomes feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: a comparison with time-of-flight MR angiography.

The combination of 3T and parallel-acquisition techniques holds promise for improved performance of contrast-enhanced MR angiography (MRA), in terms of speed, spatial resolution, and coverage. We present a comparison of 2 MRA techniques, including time-of-flight (TOF) and contrast-enhanced MRA, for detection and evaluation of intracranial aneurysms. Our results show that contrast-enhanced MRA w...

متن کامل

Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: a technical note.

Time-resolved, contrast-enhanced 3D MR angiography combined with parallel imaging at 3T was applied to an intracranial arteriovenous malformation, a dural arteriovenous fistula, and an extracranial facial arteriovenous malformation. The temporal resolution was one image every 1.5 seconds. Arterial feeders were depicted in all three cases. Early venous drainage was observed in the intracerebral ...

متن کامل

Comprehensive Magnetic Resonance evaluation of vascular malformations at 3T: comparison of Time-resolved Angiography With Interleaved Stochastic Trajectories (TWIST) with standard 3D contrast enhanced MR Angiography (ceMRA)

(A) TWIST image in early arterial phase showing capillary lakes (arrow head). (B) TWIST image 2.2 sec after (A) showing development of tiny early draining veins (arrow). (C) Standard 3d ceMRA in the arterial phase demonstrating significant venous contamination without evidence of capillary shunting. Comprehensive Magnetic Resonance evaluation of vascular malformations at 3T: comparison of Time-...

متن کامل

3T high-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with parallel imaging.

The diagnostic image quality of contrast-enhanced (CE) 3D MR venography (MRV) was prospectively compared with that of 2D time-of-flight (TOF) MRV and contrast-enhanced 3D magnetization-prepared rapid acquisition of gradient echo (MPRAGE) sequences for the visualization of the intracranial venous system at 3T in 22 patients. CE MRV provides high-quality images and was shown to be superior to TOF...

متن کامل

Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stochastic trajectories (TWIST) with standard high-resolution 3D contrast enhance MR Angiography (HR ceMRA)

¶ Figure 3: Calf station of left lower limb in patient with normal runoff arteries. (A) TWIST demonstrates focal occlusion of the distal anterior tibial artery (arrow) and a high grade stenosis of the distal posterior tibial artery (arrowhead) (B) HR ceMRA demonstrating normally appearing runoff arteries. Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stoc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2006